Retrospective Cardiac Gating with A Prototype Small-Animal X-ray Computed Tomograph
Published on: February 21, 2025
Detection of ground-glass opacities by use of hybrid iterative reconstruction (iDose) and low-dose 256-section
Ko Higuchi1, Michinobu Nagao, Yoshio Matsuo
1Department of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-Ku, Fukuoka-city, Fukuoka 812-8582, Japan. khiguchi@radiol.med.kyushu-u.ac.jp
Abstract:
The detection of ground-glass opacities (GGOs) is an important issue in lung cancer screening with low-dose CT. The iterative reconstruction (IR) technique has the ability to improve the image quality relative to the filtered back projection (FBP) technique with low-dose CT. Our purpose was to investigate the ability to detect GGO in a chest phantom using a low-dose CT and hybrid IR, named iDose. Simulated GGOs in a chest phantom were scanned with 256-section CT at tube current second products of 20, 50, 100, and 200 mAs. Five radiologists visually assessed the detectability of GGOs in the phantom. The contrast-to-noise ratio (CNR) for GGOs was used as an estimate of image quality. Comparison of the detectability and CNR between standard images with 200 mAs-FBP and low-dose images with 20, 50, and 100-mAs FBP/iDose were performed by ANOVA with Dunnett's and Tukey's test. The detectability was significantly lower at 20-mAs FBP/iDose and 50-mAs FBP than that at 200-mAs FBP (p < 0.05). There was no significant difference between 50-mAs iDose and 200-mAs FBP and between 100-mAs iDose/FBP and 200-mAs FBP. The CNR was significantly higher on iDose images than that on FBP images at each mAs value. The CNR at 200-mAs FBP was the same as that at 50-mAs iDose (CNR:1.8). The hybrid IR technique and low-dose CT imaging with 50 mAs enabled noise and to maintain the detectability for GGOs in a chest phantom that is equivalent to the reference acquisitions of 200 mAs with FBP.
More Related Videos
12:32Image Rendering Techniques in Postmortem Computed Tomography: Evaluation of Biological Health and Profile in Stranded Cetaceans
Published on: September 27, 2020
08:36Multi-Tracer Studies of Brain Oxygen and Glucose Metabolism Using a Time-of-Flight Positron Emission Tomography-Computed Tomography Scanner
Published on: June 7, 2024
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
X-ray Imaging