Cardiac Magnetic Resonance Imaging at 7 Tesla
Published on: January 6, 2019
Application of chemical exchange saturation transfer (CEST) MRI for endogenous contrast at 7 Tesla
Adrienne N Dula1, Seth A Smith, John C Gore
1Vanderbilt University Institute of Imaging Science, Nashville, Tennessee; Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, Tennessee.
Abstract:
Chemical exchange saturation transfer (CEST) magnetic resonance imaging (MRI) indirectly images exchangeable solute protons resonating at frequencies different than bulk water. These solute protons are selectively saturated using low bandwidth RF irradiation and saturation is transferred to bulk water protons via chemical exchange, resulting in an attenuation of the measured water proton signal. CEST MRI is an advanced MRI technique with wide application potential due to the ability to examine complex molecular contributions. CEST MRI at high field (7 Tesla [7 T]) will improve the overall results due to increase in signal, T1 relaxation time, and chemical shift dispersion. Increased field strength translates to enhanced quantification of the metabolite of interest, allowing more fundamental studies on underlying pathophysiology. CEST contrast is affected by several tissue properties, such as the concentrations of exchange partners and their rate of proton exchange, whose effects have been examined and explored in this review. We have highlighted the background of CEST MRI, typical implementation strategy, and complications at 7 T.
More Related Videos
08:51Magnetic Resonance Imaging of Multiple Sclerosis at 7.0 Tesla
Published on: February 19, 2021
13:56The Use of Magnetic Resonance Spectroscopy as a Tool for the Measurement of Bi-hemispheric Transcranial Electric Stimulation Effects on Primary Motor Cortex Metabolism
Published on: November 19, 2014
Related Concept Videos
Magnetic Resonance Imaging
Insensitive Nuclei Enhanced by Polarization Transfer (INEPT)
¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
Chemical Shift: Internal References and Solvent Effects
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...