[Safety and electromagnetic compatibility in sanitary field]

M Bini1, P Feroldi, C Ferri

  • 1Istituto di Fisica Applicata, IFAC-CNR, Firenze.

Summary

The Italian Si.C.E.O. project assessed non-ionizing radiation risks in hospitals, analyzing indoor and outdoor sources to protect patients, staff, and the public from electromagnetic fields.

Related Concept Videos

Insulation Coordination01:23

Insulation Coordination

Insulation coordination is the process of matching electric equipment's insulation strength with protective device characteristics to protect the equipment against expected overvoltages. This selection is based on engineering judgment and cost. Equipment can generally withstand short-duration high transient overvoltages, but repeated tests with identical waveforms can yield inconsistent results. As a result, standard impulse voltage waveforms are used for testing, defined by specific times for...
Household Wiring And Electrical Safety01:13

Household Wiring And Electrical Safety

Companies that supply power to most modern households use three conductors, typically called a three-wire line. While one is neutral, the other two are both at 120 V but with opposite polarity, giving a voltage of 240 V between them. With a three-wire line, high-power appliances that require 240 V, such as electric stoves and clothes dryers, are linked between the two hot lines. 120 V appliances can be connected between the neutral and either of the hot lines. The neutral side, which is always...
Electromagnetic Fields01:30

Electromagnetic Fields

Electric fields generated by static charges, often referred to as electrostatic fields, are characteristically different from electric fields created by time-varying magnetic fields. While the former is a conservative field, implying that no net work is done on a test charge if it goes around in a complete loop in the field, the latter is, by definition, not a conservative field; net work is done, and it is proportional to the rate of change of magnetic flux.
However, the observation of Gauss's...
Applications of EMF Measurements01:26

Applications of EMF Measurements

Electromotive force (EMF) measurements have a broad range of applications in various fields, including chemistry and physics. The electrochemical series, an arrangement of elements in order of their standard electrode potentials, can be determined through EMF measurements. Elements with lower standard potentials can reduce ions of elements with higher standard potentials.The standard cell potential, E°, allows for the calculation of the standard reaction Gibbs energy, ΔG°, and the equilibrium...
Cleaning, Sterilization, and Disinfection01:30

Cleaning, Sterilization, and Disinfection

Cleaning, disinfection, and sterilization are the methods that help to break the infection chain and prevent disease.
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Zones of Protection01:16

Zones of Protection

In power systems, the entire setup is divided into protective zones to isolate faults and protect the rest of the network. These zones include generators, transformers, buses, transmission lines, distribution lines, and motors. Each zone can be visualized as a separate room in a house, with each room protected by its own circuit breaker.
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...