Related Concept Videos

Methods of Medium Optimization01:28

Methods of Medium Optimization

Optimizing growth media enhances microbial proliferation and maximizes product yield. Statistical experimental design methodologies provide structured and reproducible approaches, offering progressively higher levels of robustness and efficiency.The One-Factor-at-a-Time (OFAT) MethodThe One-Factor-at-a-Time (OFAT) method involves adjusting a single variable while keeping all others constant. However, it cannot detect interactions between variables, often leading to suboptimal outcomes when...
The Midpoint Formula01:24

The Midpoint Formula

In coordinate geometry, determining the central point between two locations is common. This central point, or midpoint, lies exactly halfway along the line segment connecting two points in a two-dimensional space. It has applications in mathematics, physics, engineering, and various planning disciplines.Given two points labeled as A (x1, y1) and B (x2, y2) on a coordinate plane, a straight line segment can be plotted between them. The midpoint, labeled point M, divides this segment into two...
Fast Fourier Transform01:10

Fast Fourier Transform

The Fast Fourier Transform (FFT) is a computational algorithm designed to compute the Discrete Fourier Transform (DFT) efficiently. By breaking down the calculations into smaller, manageable sections, the FFT significantly reduces the computational complexity involved. Direct computation of an N-point DFT requires N2 complex multiplications, whereas the FFT algorithm needs only (N/2)log⁡2N multiplications, offering a much faster performance.
The computational efficiency of the FFT becomes...
Fast Decoupled and DC Powerflow01:24

Fast Decoupled and DC Powerflow

The fast decoupled power flow method addresses contingencies in power system operations, such as generator outages or transmission line failures. This method provides quick power flow solutions, essential for real-time system adjustments. Fast decoupled power flow algorithms simplify the Jacobian matrix by neglecting certain elements, leading to two sets of decoupled equations:
Mesh Analysis for AC Circuits01:12

Mesh Analysis for AC Circuits

In the domain of radio communication, the significance of impedance matching must be considered. It is crucial to ensure the efficient transmission of signals between radio transmitters and receivers. Achieving this balance involves using impedance-matching circuits, with one fundamental configuration comprising a resistor, capacitor, and inductor.
The process of harmonizing these impedances begins with a clear understanding of the input and output signals. Once these signals are known, the...
Maximum Power Transfer01:16

Maximum Power Transfer

Numerous practical applications within engineering disciplines, such as telecommunications, necessitate optimizing power delivery to a connected load. This pursuit, however, entails inherent internal losses, which can either equal or exceed the power supplied to the load. The Thevenin equivalent circuit is helpful in finding the maximum power a linear circuit can deliver to a load. It is assumed in this context that the load resistance can be adjusted.
By substituting the entire circuit with...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Effect of an air layer on the design of high-permittivity material helmets for 7 T magnetic resonance imaging.

Magma (New York, N.Y.)·2026
Same author

First-Order Spatial Encoding Simulations for Improved Accuracy in the Presence of Strong B<sub>0</sub> and Gradient Field Variations.

Magnetic resonance in medicine·2025
Same author

Transfontanelle Thermoacoustic Imaging of Intraventricular Brain Hemorrhages in Live Sheep.

IEEE transactions on medical imaging·2025
Same author

Evaluation of a Low-Cost Amplifier With System Optimization in Thermoacoustic Tomography: Characterization and Imaging of Ex-Vivo and In-Vivo Samples.

IEEE transactions on bio-medical engineering·2025
Same author

Multiple cation insertion into a polyaromatic hydrocarbon guided by data and computation.

Chemical science·2025
Same author

Discovering trends in big data: general discussion.

Faraday discussions·2024
Same journal

A Comparison of Tissue Property Values Estimated Using Conventional Cardiac MRF and MT-Cardiac MRF.

Magnetic resonance in medicine·2026
Same journal

Dependence of the Extra-Cellular Diffusion Coefficient on the Fractions of Neurites and Cell Bodies in Gray Matter.

Magnetic resonance in medicine·2026
Same journal

Triple-Pulse <sup>23</sup>Na MRI Sequence (TriNa) for Simultaneous Acquisition of Spin-Density-Weighted and Fluid-Attenuated Images.

Magnetic resonance in medicine·2026
Same journal

Evaluation of Phantom Doping Materials in Quantitative Susceptibility Mapping.

Magnetic resonance in medicine·2026
Same journal

Design of an 8-Channel Transmit 32-Channel Receive 11.7T Head Coil and Evaluation of SNR Gains.

Magnetic resonance in medicine·2026
Same journal

The Potential for Absolute Temperature Imaging Based on Brain Metabolites Using an FID-Shifting Approach in Gradient Echo Planar Spectroscopic Imaging (GREPSI).

Magnetic resonance in medicine·2026
See all related articles

Related Experiment Video

Updated: May 14, 2026

Optimization of Radiochemical Reactions using Droplet Arrays
10:54

Optimization of Radiochemical Reactions using Droplet Arrays

Published on: February 12, 2021

A fast, analytically based method to optimize local transmit efficiency for a transmit array.

Giuseppe Carluccio1, Christopher M Collins, Danilo Erricolo

  • 1Department of Radiology, New York University, New York, New York, USA.

Magnetic Resonance in Medicine
|February 16, 2013
PubMed
Summary
This summary is machine-generated.

This study introduces an analytical algorithm to optimize radiofrequency magnetic (B1+) field intensity in transmit arrays. The method enhances B1+ field strength while minimizing whole-body specific absorption rate, improving MRI safety and efficiency.

Keywords:
magnetic resonance imagingpowerradiofrequencyshimmingspecific absorption ratespectroscopy

Related Experiment Videos

Last Updated: May 14, 2026

Optimization of Radiochemical Reactions using Droplet Arrays
10:54

Optimization of Radiochemical Reactions using Droplet Arrays

Published on: February 12, 2021

Area of Science:

  • Magnetic Resonance Imaging (MRI)
  • Biomedical Engineering
  • Radiofrequency Engineering

Background:

  • Optimizing radiofrequency (RF) magnetic field (B1+) intensity is crucial for MRI.
  • Transmit arrays offer advanced B1+ field control but require sophisticated optimization.
  • Minimizing specific absorption rate (SAR) is essential for patient safety in MRI.

Purpose of the Study:

  • To develop a rapid, analytical algorithm for optimizing B1+ field intensity in RF transmit arrays.
  • To provide insights into B1+ field optimization requirements.
  • To establish a reference for numerical optimization methods.

Main Methods:

  • Utilized knowledge of B1+ field distribution from individual array coils.
  • Optimized coil current phases and amplitudes to maximize B1+ field magnitude per unit of transmitted power.
  • Focused on minimizing whole-body specific absorption rate (SAR) for specific pulse sequences.

Main Results:

  • Simulations demonstrated significant SAR reduction for a given B1+ magnitude.
  • Achieved a ~6.3-fold SAR reduction compared to birdcage configurations.
  • Showed a ~3.2-fold SAR reduction versus phase-only shimming with coil coupling.

Conclusions:

  • The developed analytical method rapidly provides crucial information for optimizing transmit array field distributions.
  • This approach enhances MRI performance and safety by improving B1+ field control and reducing SAR.
  • Offers a valuable tool for researchers and engineers in MRI technology development.