Left main coronary artery bidirectional dissection caused by ejection of guideliner catheter from the guiding catheter
Related Experiment Video
Updated: May 14, 2026

Chronic Ovine Model of Right Ventricular Failure and Functional Tricuspid Regurgitation
Published on: March 17, 2023
Yi-Chih Chang1, Hsiu-Yu Fang, Tien-Hsing Chen
1Division of Cardiology, Xiamen Chang Gung Hospital, China.
Insights
The Guideliner catheter aids complex coronary lesion treatment but carries risks. This case highlights a rare Guideliner-induced left main dissection, emphasizing the need for awareness of potential complications during percutaneous coronary intervention.
Area of Science:
- Interventional Cardiology
- Medical Device Technology
Background:
- The Guideliner catheter is designed for complex coronary lesions, offering deep engagement and support for stent delivery.
- Percutaneous coronary intervention (PCI) complications include coronary artery dissection, often linked to catheter manipulation.
Observation:
- A case of Guideliner-induced left main dissection is presented following successful revascularization.
- This complication occurred after treating chronic total occlusions in the left anterior descending and left circumflex arteries.
Findings:
- The Guideliner catheter, while effective for complex lesions, was associated with an uncommonly reported left main dissection.
- Deep engagement or noncoaxial alignment of catheters can increase dissection risk.
Implications:
- Awareness of the Guideliner catheter's potential for causing dissection is crucial for interventional cardiologists.
- Careful technique and patient selection are necessary to mitigate risks associated with advanced delivery systems in PCI.
Abstract:
The "Guideliner," a child catheter, aims to deliver stents in tortuous coronary lesions by deep engagement and providing better support. Coronary artery spiral dissection, which may be caused by deep-seated coronary catheters or noncoaxial engagement is one of the most seen percutaneous coronary intervention-related complications. In this case, Guideliner-related left main dissection occurred after successful revascularization of a chronic total occlusion at the left anterior descending artery and the left circumflex, which has not been previously reported. The Guideliner catheter is efficient in treating complex coronary lesions, but one should be aware of its related complications.
More Related Videos
05:41Left Anterior Descending Coronary Artery Ligation for Ischemia-Reperfusion Research: Model Improvement via Technical Modifications and Quality Control
Published on: December 16, 2022
13:10Direct Re-implantation of Left Coronary Artery into the Aorta in Adults with Anomalous Origin of Left Coronary Artery from the Pulmonary Artery (ALCAPA)
Published on: April 24, 2017
Related Concept Videos
Cardiac Catheterization III: Left Heart Catheterization
Cardiac Catheterization II: Right Heart Catheterization
Cardiac Catheterization I: Pre-Procedure Overview