Related Concept Videos

Drug Control Governance: Regulatory Bodies and Their Impact01:03

Drug Control Governance: Regulatory Bodies and Their Impact

Drug control governance involves the oversight and regulation of pharmaceuticals to ensure their safety and efficacy while preventing illegal drug use and trafficking. Regulatory bodies, including the US Food and Drug Administration (FDA) and the European Union's European Medicines Agency (EMA), play a central role in this process. These agencies evaluate the safety and efficacy of drugs before they can be marketed. They fund clinical trials and assess the benefits and risks associated with a...
Atomic Absorption Spectroscopy: Instrumentation01:22

Atomic Absorption Spectroscopy: Instrumentation

An atomic absorption spectrophotometer (AAS) comprises several components: a radiation source, an atomizer, a monochromator, and a detector. The radiation source can be a hollow-cathode lamp (HCL) or an electrodeless-discharge lamp (EDL), both of which provide a narrow emission line of the required wavelength. However, some instruments use continuum sources and high-resolution monochromators to achieve a narrow range of radiation.
The atomizer used in AAS can be either a flame atomizer or an...
Atomic Absorption Spectroscopy: Interference01:25

Atomic Absorption Spectroscopy: Interference

Interference leads to systematic error in atomic absorption (AA) measurements by enhancing or diminishing the analytical signal or the background. These interferences can be grouped into three main categories: spectral interference, chemical interference, and physical interference.
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Atomic Absorption Spectroscopy: Lab01:21

Atomic Absorption Spectroscopy: Lab

For AAS measurements, samples must be introduced as clear solutions, often requiring extensive preliminary treatment to dissolve materials like soils, animal tissues, and minerals. Common methods for sample preparation include treatment with hot mineral acids, wet ashing, combustion in closed containers, high-temperature ashing, or fusion with reagents.
 Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Therapeutic Drug Monitoring: Overview and Classification01:16

Therapeutic Drug Monitoring: Overview and Classification

Therapeutic Drug Monitoring (TDM) is a clinical practice that measures specific drug levels in a patient's blood at designated intervals to ensure the drug concentration stays within a therapeutic range. This monitoring is crucial for optimizing individual dosage regimens, enhancing therapeutic efficacy, and minimizing drug-related toxicity. TDM is vital for drugs with narrow therapeutic windows, significant variability in pharmacokinetics, and a clear correlation between plasma levels and...
Nuclear Stability03:18

Nuclear Stability

Protons and neutrons, collectively called nucleons, are packed together tightly in a nucleus. With a radius of about 10−15 meters, a nucleus is quite small compared to the radius of the entire atom, which is about 10−10 meters. Nuclei are extremely dense compared to bulk matter, averaging 1.8 × 1014 grams per cubic centimeter. If the earth’s density were equal to the average nuclear density, the earth’s radius would be only about 200 meters.
To hold positively charged protons together in the...