Related Experiment Video
Updated: May 14, 2026

High-frequency Ultrasound Imaging of Mouse Cervical Lymph Nodes
Published on: July 25, 2015
Dose and image quality of high-pitch dual source computed tomography for the evaluation of cervical lymph node status
Boris Bodelle1, Ralf W Bauer, Lara Holthaus
1Goethe University of Frankfurt, Department of Diagnostic and Interventional Radiology, Theodor-Stern-Kai 7, 60590 Frankfurt, Germany. bbodelle@googlemail.com
Purpose:
A high-pitch dual-source CT (DSCT) was compared to a standard single-source CT protocol in terms of dose and image quality for malignant lymphoma staging.
Materials And Methods:
Data from 43 patients who underwent DSCT (group 1) of the neck for staging of malignant lymphoma and 40 patients who underwent regular single source CT (group 2) were investigated retrospectively. Volume CT dose index (CTDIvol), dose length product (DLP), background noise (BN), attenuation values, signal-to-noise-ratio (SNR), scan time, effective tube current-time product (eff. mAs), subjective diagnostic image quality and artifact burden were compared.
Results:
CTDIvol (5.5 ± 0.8 mGy vs. 12.4 ± 1.4 mGy), DLP (172 ± 27 mGycm vs. 344 ± 60 mGycm, p<0.0001), eff. mAs (98 ± 15 mAs vs. 183 ± 20 mAs, p<0.0001) and scan time (0.64 ± 0.05 s vs. 8.21 ± 0.72 s) were lower for group 1. BN was higher (p<0.001) for group 1 with a mean difference of 2.6 HU. SNR for sternocleidomastoid and pectoral muscle was lower (6.6-12.3 vs. 7.8-19.1) for group 1. Subjective image quality (1.55 ± 0.6 vs. 1.42 ± 0.5) and artifact burden (1.62 ± 1.0 vs. 1.57 ± 0.9) were not rated significantly different (p=0.47 and p=0.80) with a good inter-observer agreement (κ=0.59-0.90).
Conclusion:
High-pitch DSCT allows reduction of patient dose for cervical lymphoma staging while diagnostic image quality is preserved.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies for Cardiovascular System V: CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Radiological Investigation I: X-ray and CT
