Related Experiment Video
Updated: May 14, 2026

Microelectrode Array Recording of Sinoatrial Node Firing Rate to Identify Intrinsic Cardiac Pacemaking Defects in Mice
Published on: July 5, 2021
Cycle length characteristics differentiating non-sustained from self-terminating ventricular fibrillation in Brugada
Gabriel Cismaru1, Béatrice Brembilla-Perrot, Maheshwar Pauriah
1Cardiology, CHU de Brabois, 54500 Vandoeuvre les Nancy, France.
Aims:
Limited information is available on self-terminating (ST) ventricular fibrillation (VF). Understanding spontaneous fluctuations in VF cycle length (CL) is required to identify arrhythmia that will stop before shock. Using Brugada syndrome (BS) as a model, the purpose of the study was to compare ST-VF and VF terminated by electrical shock and to look for spontaneous fluctuations in ventricular CL.
Methods And Results:
Occurrence of ST-VF and VF was studied in 53 patients with 46 VF episodes: (i) spontaneously, (ii) during defibrillation threshold testing, (iii) during programmed ventricular stimulation (PVS). Fifteen presented ST-VF (average duration 25 s): 11 during PVS, 1 during defibrillation threshold testing, and 3 spontaneously (at device interrogation). Self-terminating ventricular fibrillation was compared with 31 VFs terminated by electrical shock. Mean ventricular CL was longer (192.5 ± 22 vs. 149 ± 19 ms) (P < 0.0001) and CL became longer or did not change in ST-VF (187 ± 28 vs. 200 ± 25 ms) (first vs. last CL)(NS) in contrast with progressively shorter CL in electrical shock-terminated VF (177 ± 14.5 vs. 139 ± 12 ms) (first vs. last CL before electrical shock) (P < 0.0001). Ventricular fibrillation had more CL variability (average 16.4 ± 6.5 ms) for the first 50 beats than ST-VF (average 4.08 ± 2) (P < 0.0001). Cycle length range for the first 50 beats was 9.6 ± 1 ms for ST-VF and 44 ± 15 for VF (P < 0.002).
Conclusion:
Self-terminating ventricular fibrillation in BS was not rare (28%). Ventricular CL was longer and progressively increased or did not change in ST-VF compared with electrical shock-terminating VF. Cycle length variability and CL range could differentiate VF and ST-VF within the first 50 beats. These parameters should be considered in the algorithms for VF detection and termination.
More Related Videos
Related Concept Videos
Dysrhythmias IV: Characteristics of Bradyarrhythmias
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
Dysrhythmias III: Characteristics of Dysrhythmias
Cardiac Action Potential
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Dysrhythmias II: Classification of Tachyarrhythmias