Related Experiment Video
Updated: May 14, 2026

Gene Regulation and Targeted Therapy in Gastric Cancer Peritoneal Metastasis: Radiological Findings from Dual Energy CT and PET/CT
Published on: January 22, 2018
Serum tumor markers and PET/CT imaging for tumor recurrence detection
Vibeke Kruse1, Veronique Cocquyt, Marleen Borms
1Division of Medical Oncology, Department of Internal Medicine, University Hopsital Ghent, De Pintelaan 185 B, 9000, Ghent, Belgium. vibeke.kruse@uzgent.be
Abstract:
When confronted with a suspicious rise in CA 15.3 in asymptomatic breast cancer patients following primary treatment and negative or equivocal conventional imaging findings, FDG PET/CT allows assessment of the site and extent of the recurring disease with an accuracy of 83%. Both FDG PET and FDG PET/CT are superior when compared to CT alone for the purpose of recurrence detection in patients suffering from ovarian carcinoma who have completed primary therapy but demonstrate a rising serum CA-125 level. As the global accuracy of CT alone for detection of recurrence of ovarian cancer approximates 80%, CT scan should be performed upfront to identify the site of recurrence. When confronted with negative or equivocal CT findings, FDG PET alone or FDG PET/CT should be added. In patients with rising serum CEA levels that have undergone primary treatment for a colorectal carcinoma, both FDG PET and FDG PET/CT allow detection of tumor recurrence with an accuracy of 95%, well above that of CT and MRI. Available studies further suggest that FDG/PET findings will affect treatment management in 28-50% of these patients. The detection rate of both 11C-choline and 18F-choline PET and PET/CT for local, regional, and distant recurrence in prostate carcinoma patients with a biochemical recurrence increases with rising PSA value at the time of imaging and reaches about 75% in patients with PSA > 3 ng/mL. Furthermore, PET and PET/CT with [11C]- and [18F]-choline derivates may be helpful in the clinical setting for optimization of individualized treatment.
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...

