High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
Published on: December 16, 2022
Contrast medium injection protocol adjusted for body surface area in combined PET/CT
Florian F Behrendt1, Marilou Rebière, Andreas Goedicke
1Department of Nuclear Medicine, RWTH Aachen University, Pauwelsstraße 30, 52057 Aachen, Germany. fbehrendt@ukaachen.de
Adjusting intravenous contrast medium dose for body surface area (BSA) in positron emission tomography/computed tomography (PET/CT) scans improves contrast enhancement consistency without impacting PET imaging results. This BSA-adjusted protocol is recommended for better standardization.
Area of Science:
- Radiology and Nuclear Medicine
- Medical Imaging Technology
- Diagnostic Imaging
Background:
- Intravenous contrast medium is crucial for numerous positron emission tomography/computed tomography (PET/CT) applications.
- Standardized contrast administration protocols are essential for reliable diagnostic imaging.
- Variability in contrast medium dose can affect image quality and diagnostic accuracy.
Purpose of the Study:
- To compare the efficacy of body surface area (BSA)-adjusted contrast medium dosing versus a fixed-dose protocol in combined PET/CT scans.
- To assess the impact of BSA adjustment on contrast enhancement homogeneity and PET tracer uptake.
- To evaluate the influence of different contrast dosing strategies on overall PET/CT image quality.
Main Methods:
- Prospective study involving 120 patients undergoing (18)F-2-deoxy-fluor-glucose ((18)F-FDG)-PET/CT.
- Patients were divided into two groups: 60 receiving a fixed 148-ml contrast dose and 60 receiving a BSA-adjusted dose.
- Measurements included standardized uptake values (SUVmean, SUVmax) and Hounsfield units (HU) for contrast enhancement; visual assessment of PET image quality was also performed.
Main Results:
- Body surface area (BSA) adjustment led to a significant decrease in the variance of contrast enhancement across all measured anatomical sites compared to the fixed-dose group.
- No statistically significant differences were observed in tracer uptake (SUVmean, SUVmax) between the BSA-adjusted and fixed-dose groups.
- Overall image quality scores showed no significant difference between the two contrast dosing protocols.
Conclusions:
- Body surface area (BSA) adjustment of intravenous contrast medium enhances interpatient consistency in contrast enhancement for PET/CT.
- This method effectively reduces the likelihood of underdosing or overdosing contrast medium.
- The BSA-adjusted contrast medium protocol is recommended for combined PET/CT imaging as it optimizes contrast enhancement without compromising PET data or image quality.