Related Experiment Video
Updated: May 14, 2026

04:41
Optimized Sealing Process and Real-Time Monitoring of Glass-to-Metal Seal Structures
Published on: September 2, 2019
Fluorescent protein senses and reports mechanical damage in glass-fiber-reinforced polymer composites
Katarzyna Makyła1, Christoph Müller, Samuel Lörcher
1Department of Chemistry, University of Basel, Klingelbergstrasse 80, 4056 Basel, Switzerland.
Advanced Materials (Deerfield Beach, Fla.)
|February 21, 2013
Abstract:
Yellow fluorescent protein (YFP) is used as a mechanoresponsive layer at the fiber/resin interface in glass-fiber-reinforced composites. The protein loses its fluorescence when subjected to mechanical stress. Within the material, it reports interfacial shear debonding and barely visible impact damage by a transition from a fluorescent to a non-fluorescent state.
Related Concept Videos
Protein Dynamics in Living Cells
Different fluorescence-based techniques are used to study the protein dynamics in living cells. These techniques include FRAP, FRET, and PET.
Fluorescent recovery after photobleaching (FRAP) is a fluorescent-protein-based detection technique used to quantify protein movement rates within the cell. This method exposes a small portion of the cell to an intense laser beam. The laser beam causes permanent photobleaching of the fluorophore-tagged proteins in the exposed region. As the bleached...
Fluorescent recovery after photobleaching (FRAP) is a fluorescent-protein-based detection technique used to quantify protein movement rates within the cell. This method exposes a small portion of the cell to an intense laser beam. The laser beam causes permanent photobleaching of the fluorophore-tagged proteins in the exposed region. As the bleached...
Studying the Cytoskeleton
The cytoskeletal architecture can be studied using different microscopic and biochemical techniques. Electron microscopy was instrumental in discovering the cytoskeletal architecture around the 1960s, which allowed obtaining structural information at a high-resolution level. However, the sample preparation procedure often limits this ability in biological samples. Several protocols have been developed over the years to optimize sample preparation. In one of the protocols known as rotary...
Reporter Genes
Reporter genes are a type of protein-coding gene that are often tagged to a gene of interest. Once inside a target cell, reporter genes usually produce visually identifiable characteristics like fluorescence and luminescence when expressed along with the gene of interest. Thus, reporter genes “report” the presence or absence of genes of interest in an organism, determine the gene expression pattern, or track the physical location of a DNA segment or protein in the cell.
Commonly used reporter...
Commonly used reporter...

