Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
Anatomical variations of the anterior cerebral arterial circle visualized by multidetector computed tomography
Jean-Christophe Ferré1, Emilie Niederberger, Xavier Morandi
1CHU Rennes, hôpital Pontchaillou, Department of Neuroradiology, 2, rue Henri-Le-Guilloux, 35000 Rennes, France. jean-christophe.ferre@chu-rennes.fr
Objectives:
Multidetector computed tomography angiography (MD-CTA) has become the first-line screening technique for patients with subarachnoid hemorrhage not only for detecting aneurysms, but also for providing decisive angioarchitectural information. The anterior cerebral arterial circle (ACAC) is the most common location for anatomical variations and aneurysms. The aim of this study was to assess the diagnostic performance of 64-section MD-CTA in the detection and characterization of anatomical variations of the ACAC compared with three-dimensional rotational angiography (3DRA).
Material And Methods:
In 104 patients, MD-CTA and 3DRA images of the internal carotid arteries were independently reviewed by two radiologists for variations, focusing on four arterial segments of the ACAC: the anterior communicating artery (ACoA); the A1 segments; the A2-A4 complexes; and the M1 segments. The percentages of variations detected by MD-CTA and 3DRA were compared using the chi-square test. Characterizations of the variations by MD-CTA compared with 3DRA were evaluated using the kappa statistic.
Results:
A total of 114 variations in 624 segments (18.3%) were detected by MD-CTA compared with 90 variations in 453 segments (19.9%) by 3DRA. The difference was not significant (P=0.56). In 453 selected segments analyzed with both techniques, 15 discordances in characterization were noted, mostly in the ACoA (10/15). However, the overall intertechnical κ was excellent. Sensitivity, specificity, positive predictive values and negative predictive values were all greater than 90%.
Conclusion:
The overall diagnostic performance of MD-CTA in detecting anatomical variations of the ACAC was excellent compared with 3DRA. However, its lower spatial resolution led to misclassifications, especially in the ACoA.
More Related Videos
06:02Anatomical Reconstructions of the Human Cardiac Venous System using Contrast-computed Tomography of Perfusion-fixed Specimens
Published on: April 18, 2013
09:36A Magnetic Resonance Imaging-based Computational Protocol for Analysis of Plaque Morphology and Hemodynamics in Patients with Carotid Artery Stenosis
Published on: August 12, 2025
Related Concept Videos
The Arch of Aorta
Encircling the heart, the coronary arteries form a ring-like structure before...
Arteries of the Head and Neck
The internal carotid arteries supply blood to the anterior portion of the cerebrum. They enter the...