A validated, rapid UPLC-MS/MS method for simultaneous ivabradine, reboxetine, and metoprolol analysis in human plasma
Alexander A Zoerner1, Christoph Schroeder, Arslan Arinc Kayacelebi
1Institute of Clinical Pharmacology, Hannover Medical School, Hannover, Germany. zoerner.alexander@mh-hannover.de
Abstract:
A recent clinical trial assessing human autonomic cardiovascular regulation applied pacemaker channel inhibition with ivabradine, norepinephrine transporter blockade with reboxetine, and beta-adrenoreceptor blockade with metoprolol. To verify patient adherence, we developed and validated a fast UPLC-MS/MS assay measuring all three compounds simultaneously. Deuterium-labeled drugs, d3-ivabradine, d5-reboxetine and d7-metoprolol, served as internal standards. Sample preparation of 200μL human plasma consisted of a single liquid-liquid extraction step by means of ethyl acetate. Chromatographic separation was performed on a 50-mm long BEH C18 column with gradient elution using a mixture of water and methanol each containing 2mM ammonium acetate over 4.5min. The mass spectrometer was operated in the positive electrospray ionization (ESI+) mode. Characteristic product ions resulting from collision-induced dissociation of unlabeled and deuterium-labeled drugs with argon were used for quantification in the selected-reaction monitoring mode. We validated the method according to the European Medicines Agency (EMA) guideline on bioanalytical method validation over the range from 1ng/mL to 500ng/mL for all three analytes. Linear responses with correlation coefficients>0.99 over that range were acquired. The LOQ value was 1ng/mL for each drug. Regulatory criteria for accuracy (80-120%) and precision (RSD<15%) were met for all drugs. The internal standard-normalized matrix factor was close to 1 for low and high analyte concentrations. We successfully measured ivabradine, reboxetine, and metoprolol concentrations in 107 human plasma samples from a clinical trial. Quality control samples processed in parallel confirmed the method's reliability in a clinical setting.
More Related Videos
06:14Optimized LC-MS/MS Method for the High-throughput Analysis of Clinical Samples of Ivacaftor, Its Major Metabolites, and Lumacaftor in Biological Fluids of Cystic Fibrosis Patients
Published on: October 15, 2017
11:17Multiplex Therapeutic Drug Monitoring by Isotope-dilution HPLC-MS/MS of Antibiotics in Critical Illnesses
Published on: August 30, 2018