Hydrophilic interaction chromatography with aerosol-based detectors (ELSD, CAD, NQAD) for polar compounds lacking a
José M Cintrón1, Donald S Risley
1Eli Lilly and Company, Pharmaceutical Sciences Research and Development and Analytical Sciences Research and Development, Lilly Research Laboratories, Indianapolis, IN 46285, USA. cintronjm@lilly.com
Abstract:
In this work, a high performance liquid chromatography (HPLC) method is reported for the separation and quantitation of a drug substance that is highly polar and lacking a chromophore in a mannitol intravenous (IV) formulation. Three polar stationary phases operated in hydrophilic interaction chromatography (HILIC) mode were evaluated in conjunction with an Alltech 800 ELSD detector. These columns were evaluated with respect to chromatographic properties such as buffer, pH and organic concentrations to identify the best stationary phase. The chromatographic method was then validated for the determination of mGlu2/3 receptor agonist (-)-(1R, 4S, 5S, 6S)-4-Amino-2-sulfonylbicyclo [3.1.0] hexane-4,6-dicarboxylic acid (LY404039) content in a mannitol IV formulation with respect to linearity (R(2) of 0.9997), repeatability (%RSD of 0.36%), accuracy, solution stability (99.56% after 24h), specificity, intra-assay precision (%RSD 0.48%) and limit of detection (LOD, ∼50 μg/mL). In addition to the Alltech 800 ELSD detector, several other aerosol-based detectors were investigated for reproducibility, linearity and LOD. These additional detectors consisted of an Alltech 3300 evaporative light scattering detector (ELSD), a nano quantity analyte detector (NQAD) and a charged aerosol detector (CAD). Based on the data from this report, a feasible isocratic LC method was achieved using a TSKgel Amide-80 column with mobile phase conditions of 30% water with 0.2% trifluoroacetic acid (TFA) and 70% acetonitrile (ACN) using any of the four aerosol-based detectors for detection and quantitation.
More Related Videos
13:35A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Gas Chromatography: Types of Detectors-II
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
High-Performance Liquid Chromatography: Elution Process