Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Theoretical tools for predicting optimal cross-sectional shapes in micro-gas chromatography
Xiaohong Yan1, Jian Yang, Qiuwang Wang
1Department of Chemical Engineering, Xi'an Jiaotong University, Xi'an, Shaanxi, China. xhyan11@mail.xjtu.edu.cn
Abstract:
It is meaningful to explore the possibility of improving the micro-GC column performance by adjusting the column cross-sectional shape. The objective of this study was to seek the column cross-sectional shape that results in larger plate number per meter than other shapes with the same cross-sectional area and the same flow resistance coefficient. We applied a model based on the volume averaging method to derive the expression of plate height for columns with arbitrary cross-sectional shapes, and conducted the shape optimization by combining the model and an optimization tool. By varying flow resistance coefficient, we obtained a series of optimal shapes. It is found that, the optimal shape with larger flow resistance coefficient is shallower and the related plate number per meter is larger. We predicted and optimized the performance of a micro-GC column reported in literature. The prediction agrees reasonably with experimental data. More than twice the plate number per meter of the original column was predicted by using a hypothetical column with one optimal cross-sectional shape.
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Column Efficiency: Plate Theory
A higher number of theoretical plates signifies better column efficiency and improved separation capabilities. Plate height affects bandwidth and separation quality; it is inversely...