Objective:
The purpose of this study is to compare the image quality of coronary CT angiography performed with and without breast shields.
Materials And Methods:
This study involved a retrospective cohort of 72 women with possible angina who underwent 64-MDCT retrospective ECG-gated coronary CT angiography at a single academic tertiary medical center. Images of 36 women scanned while wearing bismuth-coated latex breast shields and 36 control subjects scanned without shields, matched by heart rate and body mass index, were graded on a standardized Likert scale for image quality, stenosis, and plaque by two independent board-certified readers blinded to breast shields.
Results:
Seventy-two patients (mean [± SD] age, 53 ± 9 years) were included. The pre scan heart rate, body mass index, and Agatston score did not differ between groups. The median estimated radiation dose was 13.4 versus 16.1 mSv for those with and without breast shields (p = 0.003). For shielded versus unshielded scans, 86% versus 83% of coronary segments were rated excellent or above average (p = 0.4), median image quality was 2.0 for both groups, mean signal was 474 ± 75 and 452 ± 91 HU (p = 0.27), mean noise was 33.9 ± 8.5 and 29.8 ± 8.3 HU (p = 0.04), and median signal-to-noise ratio was 14.4 and 14.7 (p = 0.56), respectively.
Conclusion:
Breast shields for women undergoing coronary CT angiography slightly increased noise but did not negatively affect signal, signal-to-noise ratio, quality, or interpretability. Breast shield use warrants further study.
More Related Videos
06:57Semi-Automatic Graphical Tool for Measuring Coronary Artery Spatially Weighted Calcium Score from Gated Cardiac Computed Tomography Images
Published on: September 22, 2023
08:02Novel Quantification Protocol for Cardiovascular Calcification Progression Using Longitudinal MicroPET/MicroCT Images
Published on: November 15, 2024
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Acute Coronary Syndrome III: Diagnostic Studies
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Imaging Studies for Cardiovascular System IV: CMRI