Related Experiment Video
Updated: May 13, 2026

Functional Characterization of Carboxylesterases in Insecticide Resistant House Flies, Musca Domestica
Published on: August 23, 2018
[High performance liquid chromatography-validated analytical method for 1% permethrin quantification]
Alicia Tarinas Reyes1, Rolando D Tápanes Peraza, Ditter Fernández Rangel
1Laboratorio de Farmacología Clínica, Instituto de Medicina Tropical "Pedro Kouri" (IPK), La Habana, Cuba. ali@ipk.sld.cu
Introduction:
In Cuba, as well as in other countries, Pediculus capitis infestation has increased since the 70's; this is the reason why a program aimed at controlling and preventing this infestation was designed. This program includes quality control studies of the active synthetic pyrethroid Permethrin and its activity at 1% on lice and 5% on scabies. Due to its low toxicity and positive risk/benefit ratio, Permethrin is a pediculicide of choice to decrease Pediculus capitis infestation.
Objective:
To validate an analytical method using high performance liquid chromatography and its application in the quantification of 12 samples from 2 batches of Cuban-made 1% permethrin pediculicidal preparation.
Methods:
Linearity, precision and accuracy parameters were determined. Seven calibration standards and working solutions with concentrations ranging from 100 to 15000 microg/mL were prepared. These validation parameters were verified through the correlation coefficient, the variation coefficient and the percentage relative error.
Results:
The specificity of this method was proved in the chromatograms that showed retention times of 8,8 to 9,2 min for the isomer trans and 10,7 to 11,2 min for the isomer cis. The correlation coefficient for both isomers was higher than 0,99; the variation coefficient was under 3% and the percentage relative error was--3 and 1% for the inter-day and intraday studies, respectively. The mean permethrin concentration in 1% solution batches was estimated at 6 780,14 microg/mL.
Conclusions:
The validated method was linear, precise and exact within the range of the studied concentrations. The estimated concentration of permethrin was below the expected rate according to the composition of 1% permethrin solution (9 100-10 900 microg/mL). This method may be useful for the quantification of 1% permethrin solutions in the quality studies of the product sold to the population.
More Related Videos
04:17Analysis of Organochlorine Pesticides in a Soil Sample by a Modified QuEChERS Approach Using Ammonium Formate
Published on: January 20, 2023
05:20Determination of 45 Pesticides in Avocado Varieties by the QuEChERS Method and Gas Chromatography-Tandem Mass Spectrometry
Published on: December 8, 2023
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process: