Most Care®: a minimally invasive system for hemodynamic monitoring powered by the Pressure Recording Analytical
S Romagnoli1, S Bevilacqua, C Lazzeri
1Heart and Vessels Department, Cardiac and Vascular Anesthesia and Post-Cardiac Surgery Intensive Care Unit Careggi Hospital, Florence, Italy.
Abstract:
Invasive hemodynamic monitoring is a cornerstone of the care of critically ill and hemodynamically unstable patients in both intensive care units and operating rooms. The assessment of cardiac output by means of the pulmonary artery catheter has been considered the clinical gold standard. Nevertheless, several concerns have been raised regarding its invasiveness, usefulness, and associated complica-tions. These disadvantages have led to the development, during the last years, of a number of less invasive technologies for cardiac output determination. Among them, those based on the analysis of a peripheral arterial waveform have become commonly used. Most Care(®) is a minimally invasive arterial pressure based monitor powered by the Pressure Recording Analytical Method (PRAM), the only algorithm that does not require prior calibration or pre-calculated parameters and which is based of flow. PRAM provides the measurement of the main factors of hemodynamics, such as systemic blood pressures, stroke volume, cardiac output, and vascular resistances. Moreover, dynamic indices of fluid responsiveness are continuously displayed. In the present paper, we reviewed the current literature focusing on advantages and limitations of PRAM.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Measurement of Blood Pressure
Holter Monitor: 24-Hour Monitoring
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.