Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Experiment Video

Updated: May 13, 2026

Effects of Mechanical Methods Used in Peri-implantitis Treatment on Implant Surface Decontamination and Roughness
06:36

Effects of Mechanical Methods Used in Peri-implantitis Treatment on Implant Surface Decontamination and Roughness

Published on: March 14, 2025

Contour analysis of an implant--soft tissue interface.

W L Chai1, K Moharamzadeh, R van Noort

  • 1Department of General Dental Practice and Oral & Maxillofacial Imaging, Faculty of Dentistry, University of Malaya, Kuala Lumpur, Malaysia.

Journal of Periodontal Research
|February 28, 2013
PubMed
Summary
This summary is machine-generated.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Patient Satisfaction with Upper and Lower Complete Dentures: A Service Evaluation Report.

The European journal of prosthodontics and restorative dentistry·2022
Same author

A new classification system of trifid mandibular canal derived from Malaysian population.

Folia morphologica·2022
Same author

The Evolution of Dental Materials over the Past Century: Silver and Gold to Tooth Color and Beyond.

Journal of dental research·2019
Same author

The Effects of Colored Pigments on the Translucency of Experimental Dental Resin Composites.

The European journal of prosthodontics and restorative dentistry·2019
Same author

[Sampling Survey of the Relationship Between Acute Mountain Sickness and Mental Health of Officers and soldiers].

Zhonghua lao dong wei sheng zhi ye bing za zhi = Zhonghua laodong weisheng zhiyebing zazhi = Chinese journal of industrial hygiene and occupational diseases·2018
Same author

A Review of the Impact of Implant Biomaterials on Osteocytes.

Journal of dental research·2018

A novel impression technique successfully analyzed soft tissue contours around titanium implants using an in vitro 3D oral mucosal model. This method avoids implant removal, offering a new approach for peri-implant tissue studies.

Area of Science:

  • Biomaterials Science
  • Tissue Engineering
  • Oral Biology

Background:

  • Current methods for studying peri-implant soft tissues in vivo often require destructive techniques, such as cutting or removing implants.
  • These traditional methods hinder detailed contour analysis of the soft tissue-implant interface.

Purpose of the Study:

  • To introduce and evaluate a novel impression technique for analyzing soft tissue contours around titanium implants.
  • To assess this technique using an in vitro three-dimensional oral mucosal model (3D OMM) with varying titanium surface roughness.
  • To determine if the technique requires implant removal for contour analysis.

Main Methods:

  • A 3D OMM was created by co-culturing keratinocytes (TR146) and human oral fibroblasts on an acellular dermis scaffold.
Keywords:
dental implantepitheliumfibroblastin vitro modeltissue engineering

More Related Videos

Intravital Longitudinal Imaging of Vascular Dynamics in the Calvarial Bone Marrow
10:49

Intravital Longitudinal Imaging of Vascular Dynamics in the Calvarial Bone Marrow

Published on: April 11, 2025

Related Experiment Videos

Last Updated: May 13, 2026

Effects of Mechanical Methods Used in Peri-implantitis Treatment on Implant Surface Decontamination and Roughness
06:36

Effects of Mechanical Methods Used in Peri-implantitis Treatment on Implant Surface Decontamination and Roughness

Published on: March 14, 2025

Intravital Longitudinal Imaging of Vascular Dynamics in the Calvarial Bone Marrow
10:49

Intravital Longitudinal Imaging of Vascular Dynamics in the Calvarial Bone Marrow

Published on: April 11, 2025

  • Four types of titanium (Ti) surfaces (polished, machined, sandblasted, anodized) were tested.
  • After 10 days of culture, specimens underwent undecalcified sectioning, electropolishing, and the novel impression technique for contour analysis.
  • Main Results:

    • Microscopic examination revealed peri-implant-like epithelium attachment on all tested titanium surfaces.
    • The novel impression technique allowed for contour analysis without implant removal.
    • The most frequent contour angle observed at the implant-soft tissue interface ranged from 45° to 90°.

    Conclusions:

    • The in vitro 3D OMM successfully mimics peri-implant epithelium formation.
    • The novel impression technique provides a non-destructive method for analyzing soft tissue contours around implants.
    • No significant differences in implant-soft tissue interface contour were found among the four titanium surface types.