Related Experiment Video
Updated: May 13, 2026

13:10
Evaluation of Respiratory System Mechanics in Mice using the Forced Oscillation Technique
Published on: May 15, 2013
Manikin-based performance evaluation of elastomeric respirators against combustion particles
Xinjian He1, Michael Yermakov, Tiina Reponen
1Center for Health-Related Aerosol Studies, Department of Environmental Health, University of Cincinnati, Cincinnati, Ohio 45267, USA.
Journal of Occupational and Environmental Hygiene
|February 28, 2013
Summary
Firefighter respirator performance depends on faceseal leakage, breathing flow, and combustion material. While P-100 filters meet standards, the total inward leakage (TIL) test may not fully predict protection for half mask respirators with leaks.
Area of Science:
- Occupational Health and Safety
- Respiratory Protection
- Firefighter Safety
Background:
- Firefighters face exposure to combustion particles.
- Elastomeric respirators, including P-100 half and full facepiece models, are crucial protective equipment.
- Understanding factors influencing respirator performance is vital for ensuring adequate protection.
Purpose of the Study:
- To investigate the impact of faceseal leakage, breathing flow dynamics, and combustion material on particle penetration into P-100 respirators.
- To evaluate the effectiveness of current respirator testing protocols, specifically the NIOSH total inward leakage (TIL) test.
Main Methods:
- Respirators were tested on a breathing manikin exposed to combustion aerosols (wood, paper, plastic).
- Testing involved various cyclic and constant breathing flow rates and four faceseal conditions.
- Particle penetration was measured by comparing concentrations inside and outside the respirator.
Main Results:
- Faceseal leakage, breathing flow, and combustion material significantly affected respirator performance.
- P-100 filter efficiency met NIOSH criteria and was unaffected by aerosol type or flow.
- Increased leak size led to higher particle penetration, particularly in unsealed or partially sealed half mask respirators.
Conclusions:
- While P-100 filters are highly efficient, faceseal integrity is critical for overall respirator protection.
- The current NIOSH TIL test may underestimate protection levels for half mask respirators with imperfect seals.
- Further refinement of testing protocols is needed to accurately predict real-world respirator performance.