Background:
Tracheal intubation with conventional laryngoscopy requires many trials until beginners are sufficiently skilled in intubating patients safely. To facilitate intubation, the authors used retrograde light-guided laryngoscopy (RLGL) and compared its feasibility with conventional direct laryngoscopy (DL).
Methods:
Twenty operators participated in a prospective, randomized, open-label, parallel-arm study. These operators intubated 205 patients randomly according to a computer-generated procedure by using either DL or RLGL (five intubations with each technique). The primary outcome was the success rate of tracheal intubation. The authors evaluated the success rate of tracheal intubation, the time to glottic exposure and tracheal intubation, and the Cormack and Lehane grades.
Results:
Compared with DL, the success rate was greater in the RLGL group for all five intubations (72% vs. 47%; rate difference, 25%; 95% CI [11.84-38.16%], P < 0.001). This was associated with a shorter time to glottic exposure (median [25th and 75th percentile]; 27 [15; 42] vs. 45 [30; 73] s, P < 0.001), shorter intubation time (66 [44; 120] vs. 120 [69; 120] s, P < 0.001), and decreased throat soreness (mean ± SD; visual analog scale, 2.1 ± 0.9 vs. 3.7 ± 1.0 cm, P = 0.001) in the RLGL group compared to the DL group.
Conclusion:
RLGL is an alternative intubation technique. In our study, it enables beginners to intubate patients more successfully and quickly than conventional DL.
Related Concept Videos
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due to...
Tracheostomy Care II: Procedure
Step 1: Perform hand hygiene, and put on personal protective equipment: gown, gloves, mask and...