Related Experiment Video
Updated: Jan 30, 2026

Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Urethral dosimetry and toxicity with high-dose-rate interstitial brachytherapy for vaginal cancer
Malolan S Rajagopalan1, Neeta Kannan, Hayeon Kim
1Department of Radiation Oncology, University of Pittsburgh Cancer Institute, Pittsburgh, PA15232, USA.
Purpose:
The tolerance and complication rates of the urethra are unknown for the interstitial high-dose-rate brachytherapy (HDR-BT) for vaginal cancer.
Methods And Materials:
Patients with vaginal cancer near/involving the urethra who were treated with HDR-BT between 2008 and 2011 were included. Patients received mean external beam dose of 48.0Gy followed by mean HDR-BT dose of 4.5Gy/fraction for five fractions. With CT-based planning, the urethra was contoured from the bladder neck to the meatus. Doses were converted to the biologically equivalent dose in 2Gy/fraction (EQD2).
Results:
A total of 16 patients were included, and the EQD2D90 was 74.9Gy. The urethral volume was 1.31cm(3), and the EQD2 to 0.1 and 1cm(3) were 76.2 and 48.9Gy, respectively. Two of the 6 patients with urethral involvement developed urethral necrosis. The D90 for these 2 patients was 76.8Gy, and the urethral doses to 0.1 and 1cm(3) were 95.1 and 45.8, respectively. Those who developed severe urethral toxicity had a trend to urethral EQD2 (95.1Gy vs. 73.4Gy, p=0.1) and significantly higher dose per fraction of HDR-BT to 0.1cm(3) of the urethra (5.7Gy vs. 3.7Gy, p=0.02) when compared with those who did not develop severe urethral toxicity.
Conclusions:
This study is among the first to assess urethral dosimetry for patients treated with HDR-BT for vaginal cancer. Patients who received five fractions of higher than 5Gy/fraction to 0.1cm(3) of urethra (estimated EQD2 of 85Gy) are at increased risk of severe urethral toxicity.
Related Concept Videos
Drug Dosing in Renal Diseases: Estimation of Glomerular Filtration Rate Based on Serum Creatinine Concentration
Dose Size and Dosing Frequency: Determination Methods
Determination of Multiple Dosing Parameters: Loading and Maintenance Doses
Drug Dosing in Renal Diseases: Dose Adjustments Based on Drug Clearance and Elimination Rate Constant
Reaction Rate
The mathematical representation of the change in the concentration of reactants and products, over time, is the rate...
Rational Dosage Regimen: Maintenance Dose and Loading Dose
In most cases, drugs are administered repetitively or infused continuously to maintain a steady-state concentration in the body. At a steady...