Related Experiment Video
Updated: May 13, 2026

A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy (PRRT): 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
Revised protocol for whole-body CT for multi-trauma patients applying triphasic injection followed by a single-pass
1Department of Diagnostic Imaging, Sheba Medical Center, Tel Hashomer, Israel.
Aim:
To evaluate a revised protocol for whole-body computed tomography (CT) for multi-trauma patients in an emergency department and compare it to conventional protocols.
Materials And Methods:
Forty-two of 82 multi-trauma patients underwent unenhanced CT examinations of the head, cervical spine, and upper abdomen, followed by an arterial-phase contrast-enhanced CT examination of the thorax and a porto-venous scan of the abdomen and pelvis (conventional protocol). The other 40 patients underwent unenhanced CT examinations of the head, cervical spine, and upper abdomen, followed by a one-step acquisition of the thorax, abdomen, and pelvis using a 64-section multidetector CT (MDCT) system following a triphasic injection (revised protocol). Contrast enhancement was measured in the ascending, descending, and abdominal aorta, common iliac arteries, inferior vena cava (IVC), liver, spleen, and kidneys. Image count, radiation dose, total acquisition time, mediastinal artefacts, and image quality of each area were reviewed.
Results:
Mean enhancement values in the ascending and descending aorta were significantly greater with the conventional protocol. Enhancement of the abdominal aorta, iliac arteries, IVC, liver, spleen, and kidneys was significantly greater with the revised protocol. Mediastinal streak artefacts were present in all conventional protocol images and absent in all revised protocol images. Image quality using the revised protocol was significantly better (p < 0.002). The mean effective radiation dose was significantly lower (p = 0.005), and image number reduced (p < 0.001).
Conclusion:
The revised triphasic injection single-pass whole-body imaging protocol was superior to the conventional protocol using 64-MDCT. It enabled better vascular and abdominal parenchymal imaging with reduction in radiation dose and image overload.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography
Radiological Investigation I: X-ray and CT
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET