Related Experiment Video
Updated: May 13, 2026

Measurement of X-ray Beam Coherence along Multiple Directions Using 2-D Checkerboard Phase Grating
Published on: October 11, 2016
Two-dimensional single-shot measurement of angular dispersion for compressor alignment
A Börzsönyi1, L Mangin-Thro, G Cheriaux
1Department of Optics and Quantum Electronics, University of Szeged, P.O. Box 406, Szeged H-6701, Hungary. badam@physx.u‑szeged.hu
Abstract:
Misalignment of the stretcher-compressor stages of chirped pulse amplification (CPA) lasers can aggravate the spatiotemporal shape of ultrashort pulses. We demonstrate a simple technique for angular dispersion measurement, which offers real-time single-shot two-dimensional characterization across the entire beam profile. The accuracy of our pilot experiment approaches its current theoretical limit of 0.1 μrad/nm. Unlike the current one-dimensional techniques working in the near field, the method works in the far field; hence, it is especially appropriate for assisting the most accurate alignment of a CPA laser compressor ensuring the maximum intensity on the target.