Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Focusing of Light in the Eye01:16

Focusing of Light in the Eye

Light rays enter the eye through the cornea, a transparent dome-shaped tissue that is the eye's outermost layer. The cornea bends or refracts, light rays traveling to the pupil. The shape of the cornea determines how much of the light is bent and whether the image will be focused correctly on the retina at the back of the eye. Once the light has passed through both refraction layers, it converges into a single focal point onto a small area. This is where photoreceptors start transforming...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

[Frequency and structure of combat gunshot vascular injury in an advanced third-medical organization in a modern armed conflict].

Angiologiia i sosudistaia khirurgiia = Angiology and vascular surgery·2026
Same author

[Battle-field surgery in the beginning of 21st century].

Voenno-meditsinskii zhurnal·2018
Same author

[Modern approaches to the study of sanitary and irretrievable losses of surgical nrofile in military].

Voenno-meditsinskii zhurnal·2018
Same author

Radioprotective Properties of Neomitilan in Experimental Radiation Pneumonia.

Bulletin of experimental biology and medicine·2018
Same author

[Peculiarities of delivery of specific surgical assistance to wounded during counter-terrorist and peacemaking operations on North Caucasia].

Voenno-meditsinskii zhurnal·2012
Same author

Estimation of the ocular point spread function by retina modeling.

Optics letters·2012

Related Experiment Video

Updated: May 13, 2026

Comparison of Agreement and Accuracy using Binocular Wavefront Optometer with Autorefractor and Phoropter
05:14

Comparison of Agreement and Accuracy using Binocular Wavefront Optometer with Autorefractor and Phoropter

Published on: September 16, 2025

Improving retinal imaging by corneal refractive index matching.

N Meitav1, E N Ribak, A V Goncharov

  • 1Department of Physics, Technion-Israel Institute of Technology, Haifa 32000, Israel.

Optics Letters
|March 5, 2013
PubMed
Summary

Refractive index matching reduces corneal aberrations for clearer retinal imaging. This technique improves resolution, potentially enhancing ophthalmic imaging systems and reducing the need for active aberration correction.

More Related Videos

In Vivo Confocal Microscopy in the Diagnosis and Management of Dry Eye: A Focus on Imaging Protocols and Interpretation
08:13

In Vivo Confocal Microscopy in the Diagnosis and Management of Dry Eye: A Focus on Imaging Protocols and Interpretation

Published on: November 11, 2025

Corneal Confocal Microscopy: A Novel Non-invasive Technique to Quantify Small Fibre Pathology in Peripheral Neuropathies
11:29

Corneal Confocal Microscopy: A Novel Non-invasive Technique to Quantify Small Fibre Pathology in Peripheral Neuropathies

Published on: January 3, 2011

Related Experiment Videos

Last Updated: May 13, 2026

Comparison of Agreement and Accuracy using Binocular Wavefront Optometer with Autorefractor and Phoropter
05:14

Comparison of Agreement and Accuracy using Binocular Wavefront Optometer with Autorefractor and Phoropter

Published on: September 16, 2025

In Vivo Confocal Microscopy in the Diagnosis and Management of Dry Eye: A Focus on Imaging Protocols and Interpretation
08:13

In Vivo Confocal Microscopy in the Diagnosis and Management of Dry Eye: A Focus on Imaging Protocols and Interpretation

Published on: November 11, 2025

Corneal Confocal Microscopy: A Novel Non-invasive Technique to Quantify Small Fibre Pathology in Peripheral Neuropathies
11:29

Corneal Confocal Microscopy: A Novel Non-invasive Technique to Quantify Small Fibre Pathology in Peripheral Neuropathies

Published on: January 3, 2011

Area of Science:

  • Ophthalmology
  • Optical Engineering
  • Biomedical Imaging

Background:

  • High-resolution retinal imaging necessitates pupil dilation.
  • Pupil dilation increases exposure to corneal aberrations, degrading image quality.
  • Existing methods for aberration correction can be complex or insufficient.

Purpose of the Study:

  • To reduce optical errors caused by corneal irregularities during high-resolution retinal imaging.
  • To improve the clarity and resolution of retinal images using refractive index matching.
  • To assess the efficacy of lens-fitted goggles and aspheric plates for aberration reduction.

Main Methods:

  • Utilized lens-fitted goggles for corneal immersion and refractive index matching.
  • Employed an additional aspheric plate to minimize residual ocular spherical aberration.
  • Compared index-matching-based retinal images with directly acquired images.
  • Performed point spread function simulations using averaged ocular and corneal wavefront error.

Main Results:

  • Refractive index matching significantly diminished corneal aberrations.
  • Retinal image resolution was notably improved in subjects with normal ocular aberrations.
  • Point spread function simulations confirmed substantial improvements with corneal index matching.
  • The technique demonstrated effectiveness in reducing both corneal and ocular aberrations.

Conclusions:

  • Corneal refractive index matching is an effective strategy for enhancing retinal image quality.
  • This method offers a promising approach to improve current retinal imaging technologies.
  • The technique may reduce the complexity and requirements for active ocular aberration correction systems.