Related Experiment Video
Updated: May 13, 2026

Reduced-gravity Environment Hardware Demonstrations of a Prototype Miniaturized Flow Cytometer and Companion Microfluidic Mixing Technology
Published on: November 13, 2014
Aeroelasticity-based fluid agitation for lab-on-chips
1Singapore Institute of Manufacturing Technology, 71 Nanyang drive,, Singapore 638075. hmxia@SIMTech.a-star.edu.sg
Abstract:
In this study, we report a robust agitation method for small-volume liquids. It utilizes an elastic diaphragm as the bottom of a liquid chamber, upon which an initial tension is also applied to enhance the aeroelasticity effects at small/micro scales. As a result, spontaneous vibration of the diaphragm can be induced by an external air flow, which further provides fluid agitations. The device structure is simple and can be easily fabricated at low cost. More importantly, the vibration amplitude is controllable and varies widely from several tens to several hundred micrometers depending on the applied air pressure. The resulting agitation is effective and applicable at high viscosities of up to 900 cSt. The influences of air pressure and liquid viscosity on the vibration frequency are discussed. Potential applications of this technique for solid particle agitation, focusing and fluid mixing are also demonstrated.