Related Experiment Video
Updated: May 13, 2026

Real-time Breath Analysis by Using Secondary Nanoelectrospray Ionization Coupled to High Resolution Mass Spectrometry
Published on: March 9, 2018
Multiple breath nitrogen washout: a feasible alternative to mass spectrometry
Renee Jensen1, Sanja Stanojevic, Karyn Gibney
1Division of Respiratory Medicine, Department of Pediatrics, the Hospital for Sick Children, University of Toronto, Toronto, Canada.
Background:
The lung clearance index (LCI), measured by multiple breath washout (MBW), reflects global ventilation inhomogeneity and is a sensitive marker of early cystic fibrosis (CF) lung disease. Current evidence is based on a customized mass spectrometry system that uses sulfur hexafluoride (SF6) as a tracer gas, which is not widely available. Nitrogen (N2) washout may be better suited for clinical use and multi-center trials.
Objective:
To compare the results obtained from a N2 washout system to those generated by the SF6 based system in healthy children and children with CF.
Methods:
Children with CF were recruited from outpatient clinics; healthy children were recruited from the Research4Kids online portal. Participants performed MBWSF6 (Amis 2000, Innovision, Denmark) and MBWN2 (ExhalyzerD, EcoMedics, Switzerland) in triplicate, in random order on the same day. Agreement between systems was assessed by Bland-Altman plot.
Results:
Sixty-two healthy and 61 children with CF completed measurements on both systems. In health there was good agreement between systems (limits of agreement -0.7 to 1.9); on average N2 produced higher values of LCI (mean difference 0.58 (95% CI 0.42 to 0.74)). In CF the difference between systems was double that in health with a clear bias towards disproportionately higher LCIN2 compared to LCISF6 at higher mean values of LCI.
Conclusion:
LCIN2 and LCISF6 have similar discriminative power and intra-session repeatability but are not interchangeable. MBWN2 offers a valid new tool to investigate early obstructive lung disease in CF, but requires independent normative values.
Related Concept Videos
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Tandem Mass Spectrometry
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Mass Spectrometry: Amine Fragmentation
In amines, the number of nitrogen atoms affects the mass of the molecular ion, which is described by the nitrogen rule of mass spectrometry. This rule states that a compound containing a single or...
¹³C NMR: ¹H–¹³C Decoupling
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...

