[A new method of calibration and positioning in quantitative analysis of multicomponents by single marker]
Bing He1, Shi-Yan Yang, Yan Zhang
1Center of Drug Research, Luzhou Medical College, Luzhou 646000, China. lyhb2008@126.com
Abstract:
This paper aims to establish a new method of calibration and positioning in quantitative analysis of multicomponents by single marker (QAMS), using Shuanghuanglian oral liquid as the research object. Establishing relative correction factors with reference chlorogenic acid to other 11 active components (neochlorogenic acid, cryptochlorogenic acid, cafferic acid, forsythoside A, scutellarin, isochlorogenic acid B, isochlorogenic acid A, isochlorogenic acid C, baicalin and phillyrin wogonoside) in Shuanghuanglian oral liquid by 3 correction methods (multipoint correction, slope correction and quantitative factor correction). At the same time chromatographic peak was positioned by linear regression method. Only one standard uas used to determine the content of 12 components in Shuanghuanglian oral liquid, in stead of needing too many reference substance in quality control. The results showed that within the linear ranges, no significant differences were found in the quantitative results of 12 active constituents in 3 batches of Shuanghuanglian oral liquid determined by 3 correction methods and external standard method (ESM) or standard curve method (SCM). And this method is simpler and quicker than literature methods. The results were accurate and reliable, and had good reproducibility. While the positioning chromatographic peaks by linear regression method was more accurate than relative retention time in literature. The slope and the quantitative factor correction controlling the quality of Chinese traditional medicine is feasible and accurate.
Related Concept Videos
Quantitative Analysis
In quantitative analysis, two key measurements are made: the sample quantity and a property proportional to the amount of the analyte (the substance being analyzed). This forms the basis of the method...
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...
Titrimetric Methods: Types and Commonly Used Strategies
Blank Solutions
In some experimental cases, the reagents, solvents, or lab equipment used in...
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...