Related Experiment Video
Updated: May 13, 2026

06:08
Use of a Linear Accelerator for Conducting In Vitro Radiobiology Experiments
Published on: May 26, 2019
Commissioning of the Varian TrueBeam linear accelerator: a multi-institutional study
C Glide-Hurst1, M Bellon, R Foster
1Department of Radiation Oncology, Henry Ford Health Systems, Detroit, Michigan 48202, USA. churst2@hfhs.org
Medical Physics
|March 8, 2013
Summary
Commissioning data from five TrueBeam linear accelerators across three institutions showed excellent agreement. This multi-institutional study provides valuable comparison data for safe and high-quality beam commissioning.
Area of Science:
- Medical Physics
- Radiation Oncology
- Radiotherapy Technology
Background:
- Latest generation linear accelerators (linacs), including TrueBeam and TrueBeam STx, feature advanced capabilities like high-dose-rate flattening-filter-free (FFF) photon modes and novel control systems.
- These advanced features necessitate thorough evaluation and commissioning to ensure safe and effective clinical implementation.
Purpose of the Study:
- To evaluate the commissioning experience of five TrueBeam linacs at three different institutions.
- To compare dosimetric and mechanical parameters across multiple TrueBeam machines.
Main Methods:
- Analysis of acceptance and commissioning data from five TrueBeam linacs with 120-leaf MLCs.
- Comparison of photon beam profiles, PDD curves, output factors, electron cone factors, isocenter accuracy, MLC transmission, and dosimetric leaf gap (DLG).
- Inclusion of end-to-end testing and IMRT commissioning procedures.
Main Results:
- Excellent agreement in gantry/collimator isocentricity (0.27-0.28 mm) and overall mechanical accuracy (0.46-0.68 mm) across institutions.
- Consistent dosimetric data, with minimal variation in MLC DLG, transmission, photon beam quality (%dd(10)x), and output factors.
- Minor variations observed in output factors for small field sizes and electron cone factors for small cone sizes.
Conclusions:
- Multi-institutional TrueBeam commissioning data demonstrated excellent agreement, validating machine performance.
- This comprehensive dataset serves as a crucial reference for future TrueBeam commissioning, enhancing safety and quality in radiation therapy.