Exposure to carbon monoxide for patients and providers in an urban emergency medical service
Related Experiment Video
Updated: May 13, 2026

Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
Published on: January 29, 2011
Dominik Roth1, Andrea Bayer, Georg Schrattenbacher
1Department of Emergency Medicine, Medical University of Vienna, Vienna , Austria.
Background:
Carbon monoxide (CO) poisoning poses danger to both patients and emergency medical services (EMS) personnel, as its symptoms are nonspecific and EMS is currently not equipped to detect CO in ambient air.
Objective:
We aimed to assess the degree of non-fire-related CO exposure at the high-volume EMS system of a city with 2 million inhabitants.
Methods:
The EMS system was equipped with handheld CO detectors (Dräger Pac 3500), which were added to EMS standard backpacks and had to be carried to the patient at all times. During a period of one year, all alarms by those devices were recorded, sources of CO were confirmed by the fire department, and hospital follow-up was conducted for both patients and exposed EMS staff.
Results:
During the study period, there were 40 alarms, including two false alarms. Alarms occurred during the whole year, with a peak during the winter months. The median ambient CO concentration was 167 parts per million; gas heating systems were the main source of CO. One hundred ten patients and 108 EMS personnel were exposed. One hundred fifteen persons, including 22 EMS staff, had to be hospitalized, which represents one out of 1,000 total EMS patients.
Conclusions:
Carbon monoxide poisoning was found to be a significant matter for a high-volume EMS system. Handheld CO detectors helped in identifying those cases. Key words: carbon monoxide; emergency care, prehospital; equipment and supplies; poisoning.
More Related Videos
Related Concept Videos
Acute Respiratory Failure-III
Hypoxia
Types of Hypoxia
There are four primary types of hypoxia, each resulting from a different cause:
1. Anemic hypoxia: This type occurs due to insufficient oxygen delivery caused by a lack of red blood cells (RBCs) or RBCs with abnormal or...
Cardiopulmonary Resuscitation II: ACLS Airway Management
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:

