Related Experiment Video
Updated: May 13, 2026

Real-time Breath Analysis by Using Secondary Nanoelectrospray Ionization Coupled to High Resolution Mass Spectrometry
Published on: March 9, 2018
Near real-time VOCs analysis using an aspiration ion mobility spectrometer
Paweł Mochalski1, Joanna Rudnicka, Agapios Agapiou
1Breath Research Institute of the Austrian Academy of Sciences, Rathausplatz 4, A-6850 Dornbirn, Austria.
Abstract:
The ChemPro 100i chemical detector (aspiration-type ion mobility spectrometer) was used for the detection of selected volatile organic compounds known to be potential indicators of human presence. The targeted group of compounds mainly comprised ketones (acetone, 2-butanone, 2-pentanone, 3-methyl-2-butanone, 4-heptanone), aldehydes (propanal, pentanal, hexanal, octanal), dimethyl disulfide (DMDS), isoprene and ethanol. Gaseous standards of these compounds were produced from pure substances and analysed using the aspiration ion mobility spectrometry (AIMS) chemical detector. The chemical fingerprints obtained (patterns) were compared to evaluate possible differences in responses. The limits of detection ranged from 5 ppbv for 4-heptanone to 87 ppbv for DMDS, whereas relative standard deviations varied from 1.5% to 5%. Additionally, quantitative AIMS measurements of acetone levels in human breath samples were carried out. The breath acetone levels measured with AIMS ranged from 290 to 540 ppbv and correlated quite well with the SPME-GC-MS results, showing limited potential of AIMS for the detection of breath acetone; however, deviations were observed for concentrations above 500 ppbv. The further success of AIMS in breath analysis depends on improvements of the analytical power (e.g. selectivity, sensitivity, resolution) and the implementation of multivariate data analysis techniques.
More Related Videos
08:43PTR-ToF-MS Coupled with an Automated Sampling System and Tailored Data Analysis for Food Studies: Bioprocess Monitoring, Screening and Nose-space Analysis
Published on: May 11, 2017
09:19Capturing Actively Produced Microbial Volatile Organic Compounds from Human-Associated Samples with Vacuum-Assisted Sorbent Extraction
Published on: June 1, 2022
Related Concept Videos
Chemical Ionization (CI) Mass Spectrometry
Atomic Absorption Spectroscopy: Atomization Methods
Mass Spectrometers
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
IR Spectroscopy: Molecular Vibration Overview
Stretching vibrations are vibrational motions that occur along the bond line, changing the bond length or distance between two bonded atoms. They are further distinguished as symmetric or asymmetric. In symmetric stretching, the...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...