Related Experiment Video
Updated: Mar 1, 2026

Novel Techniques for Observing Structural Dynamics of Photoresponsive Liquid Crystals
Published on: May 29, 2018
Study of light transport inside scintillation crystals for PET detectors
Xin Yang1, Evan Downie, Thomas Farrell
1Department of Medical Physics and Applied Radiation Sciences, McMaster University, Hamilton, Ontario, Canada.
Abstract:
Scintillation crystal design is a critical component in positron emission tomography system development, which impacts a number of performance parameters including energy resolution, time resolution and spatial resolution. Our work aims to develop a generalized simulation tool to model the light transport inside scintillation crystals with good accuracy, taking into account surface treatments, reflectors, temporal dependence of scintillation decay, and comprehensive experimental validations. The simulation has been validated against both direct analytical calculation and experimental measurements. In this work, the studies were performed for a lutetium-yttrium oxyorthosilicate crystal of 3×3×20 mm(3) dimension coupled to a Hamamatsu silicon photomultiplier, with respect to light output, rise-time slope, energy resolution and time resolution. Four crystal surface treatment and reflector configurations were investigated: GroundMetal, GroundPaint, PolishMetal and PolishPaint. The experiments were performed to validate the Monte Carlo simulation results. The results indicate that the best time resolution (0.96±0.05 ns) and good energy resolution (10.6±0.4%) could be produced by using a polished surface with specular reflector, while the configuration of a polished surface with diffusive reflector produces the best energy resolution (10.2±0.9%). The results indicate that a polished surface with diffusive reflector achieves the best energy resolution (10.2±0.9%) for 511 keV high energy photons, and a polished surface with specular reflector achieves the best time resolution (0.96±0.05 ns) measured against a Hamamatsu fast photomultiplier tube. The ground surface treatment is not recommended for its inferior performance in terms of energy and time resolution. Possible explanations and future improvements to be made to the developed simulation tool are discussed.
More Related Videos
11:27Studying Soft-matter and Biological Systems over a Wide Length-scale from Nanometer and Micrometer Sizes at the Small-angle Neutron Diffractometer KWS-2
Published on: December 8, 2016
11:08Fabrication And Characterization Of Photonic Crystal Slow Light Waveguides And Cavities
Published on: November 30, 2012
Related Concept Videos
Determination of Crystal Structures
Photoluminescence: Applications
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET