Related Experiment Video
Updated: May 13, 2026

Detection of Architectural Distortion in Prior Mammograms via Analysis of Oriented Patterns
Published on: August 30, 2013
Diagnostic imaging and biopsy pathways following abnormal screen-film and digital screening mammography
Rebecca A Hubbard1, Weiwei Zhu, Ruslan Horblyuk
1Group Health Research Institute, Group Health Cooperative, 1730 Minor Ave, Suite 1600, Seattle, WA 98101, USA. hubbard.r@ghc.org
Abstract:
The transition from screen-film to digital mammography may have altered diagnostic evaluation of women following a positive screening examination. This study compared the use and timeliness of diagnostic imaging and biopsy for women screened with screen-film or digital mammography. Data were obtained from 35,321 positive screening mammograms on 32,087 women aged 40-89 years, from 22 breast cancer surveillance consortium facilities in 2005-2008. Diagnostic pathways were classified by their inclusion of diagnostic mammography, ultrasound, magnetic resonance imaging, and biopsy. We compared time to resolution and frequency of diagnostic pathways by patient characteristics, screening exam modality, and radiology facility. Between-facility differences were evaluated by computing the proportion of mammograms receiving follow-up with a particular pathway for each facility and examining variation in these proportions across facilities. Multinomial logistic regression adjusting for age, calendar year, and facility compared odds of follow-up with each pathway. The median time to resolution of a positive screening mammogram was 10 days. Compared to screen-film mammograms, digital mammograms were more frequently followed by only a single diagnostic mammogram (46 vs. 36 %). Pathways following digital screening mammography were also less likely to include biopsy (16 vs. 20 %). However, in adjusted analyses, most differences were not statistically significant (p = 0.857 for mammography only; p = 0.03 for biopsy). Substantial variability in diagnostic pathway frequency was seen across facilities. For instance, the frequency of evaluation with diagnostic mammography alone ranged from 23 to 55 % across facilities. Differences in evaluation of positive digital and screen-film screening mammograms were minor, and appeared to be largely attributable to substantial variation between radiology facilities. To guide health systems in their efforts to eliminate practices that do not contribute to effective care, we need further research to identify the causes of this variation and the best evidence-based approach for follow-up.
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Radiological Investigation I: X-ray and CT