Prenatal sonography can predict degree of placental invasion
K M Chalubinski1, S Pils, K Klein
1Department of Obstetrics and Gynecology, Medical University of Vienna, Vienna, Austria.
Objective:
To evaluate whether the maximum degree of placental invasion (placenta accreta, increta or percreta) can be predicted with ultrasound imaging, using criteria developed in our department.
Methods:
This was a retrospective study of all 232 patients at risk for placental invasion who were part of a routine screening program for placental invasion from January 2001 to January 2011. The whole placenta was scanned in a systematic manner using both gray-scale ultrasound and color-flow mapping. Sonographic findings were compared with the clinical outcome during and after delivery and the histomorphological examination of the placenta.
Results:
Placental invasion was suspected by ultrasound in 40 (17.2%) patients and was clinically/histopathologically confirmed in a total of 35 (15.1%) patients. The sensitivity, specificity and positive and negative predictive values of ultrasound for placental invasion were 91.4% (95% CI, 77.6-97.0%), 95.9% (95% CI, 92.2-97.9%), 80.0% (95% CI, 65.2-89.5%) and 98.4% (95% CI, 95.5-99.5%), respectively. No case of placenta increta (n = 7) or percreta (n = 17) was diagnosed as showing normal placentation or placenta accreta on ultrasound, giving an overall accuracy for the differentiation between normal placentation/placenta accreta and placenta increta/percreta of 100%.
Conclusion:
Our data suggest that prediction of the degree of placental invasion is possible using prenatal ultrasound, with high overall accuracy.
More Related Videos
09:51Model Surgical Training: Skills Acquisition in Fetoscopic Laser Photocoagulation of Monochorionic Diamniotic Twin Placenta Using Realistic Simulators
Published on: March 21, 2018
09:04Guide Wire Assisted Catheterization and Colored Dye Injection for Vascular Mapping of Monochorionic Twin Placentas
Published on: September 5, 2011
Related Concept Videos
Ultrasonography
During an ultrasonography procedure, a handheld device called a...
Imaging Studies II: Ultrasonography