Related Experiment Video
Updated: May 13, 2026

Integration of Brain Tissue Saturation Monitoring in Cardiopulmonary Exercise Testing in Patients with Heart Failure
Published on: October 1, 2019
The analysis of transesophageal oxygen saturation photoplethysmography from different signal sources
1Department of Anesthesiology, West China Hospital, Sichuan University, Chengdu 610072, China.
Abstract:
The photoplethysmography (PPG) signals detected by transesophageal oximetry sensor toward aorta arch (AA), descending aorta (DA), and left ventricle (LV) under the guidance of transesophageal echocardiography (TEE) were investigated, and the effects of filter application on PPG signals were evaluated. Eleven cardiac surgical patients were involved. After anesthesia was induced, the TEE probe with a modified pulse oximetry sensor was inserted. Under the guidance of TEE, the AA PPG, DA PPG and LV PPG were detected respectively when ventilator was on and off. The mean alternating current (AC) amplitudes and direct current (DC) values of original and filtered PPG signals were measured. The ratio of AC and DC value (AC/DC) and ventilation-induced AC variations were calculated. Satisfactory PPG waveforms were obtained in all patients under the guidance of TEE. The AC amplitude in LV PPG was significant larger than in AA and DA PPG, and both AC/DC and ventilation-induced AC variation in LV PPG were significantly higher than in AA PPG or DA PPG either. There were no significant differences of AC amplitude between filtered and ventilation off PPG signals. The AC amplitudes and AC/DC toward LV are significantly higher than transesophageal oximeter toward AA or DA, and the effect of mechanical ventilation on transesophageal PPG can be obviously reduced by filtering techniques.
More Related Videos
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.