Related Experiment Video
Updated: May 13, 2026

Fragility Assessment of Bovine Cortical Bone Using Scratch Tests
Published on: November 30, 2017
Weibull modulus and fracture strength of highly porous hydroxyapatite
X Fan1, E D Case, I Gheorghita
1Chemical Engineering and Materials Science Department, Michigan State University, East Lansing, MI 48824, USA.
Abstract:
Porous hydroxyapatite (HA) is used in a variety of applications including biomedical materials such as engineered bone materials and microbe filters. Despite the utility of the Weibull modulus, m, as a gauge of the mechanical reliability of brittle solids, there have been very few studies of m for porous HA. A recent study of porous HA that included the current authors (Fan, X., Case, E.D., Ren, F., Shu, Y., Baumann, M.J., 2012a. Journal of the Mechanical Behavior of Biomedical Materials. 8, 21-36) showed increases in m for porosity, P, approaching PG, the porosity of the green (unfired) specimen. In this paper, 18 groups of highly porous HA specimens (12 groups fabricated in this study and 6 groups from Fan et al., 2012a) were analyzed with P values from 0.59 to 0.62, where PG=0.62. The partially sintered HA specimens were fractured in biaxial flexure using a ring-on-ring test fixture. The fracture strength decreased monotonically with decreasing sintering temperature, Tsinter, from 4.8MPa for specimens sintered at 1025°C-0.66MPa for specimens sintered at 350°C. However, the Weibull modulus remained surprisingly high, ranging from 6.6 to 15.5. In comparison, for HA specimens with intermediate values of P, from about 0.1-0.55, the Weibull modulus tended to be lower (ranging from about 4 to 11) than the highly porous specimens included in this study.
Related Concept Videos
Porosity in Cement Paste
The balance of water to cement in the mix is critical—it...
Relation between Poisson's ratio, Modulus of Elasticity and Modulus of Rigidity
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the procedure...
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by a...
Porosity and Absorption of Aggregate
When all pores in an aggregate are filled with water, the aggregate is considered saturated and surface-dry. If left in dry air, water will evaporate until the aggregate...
Toughness and Hardness of Aggregate

