Related Experiment Video
Updated: May 13, 2026

Using Extraordinary Optical Transmission to Quantify Cardiac Biomarkers in Human Serum
Published on: December 13, 2017
Are troponin assays occasionally deceiving us?
Dimitrios Ntelios1, Eleftheria Mpei, Eleftheria Gousi
1Department of Internal Medicine, Volos General Hospital, 38222 Volos, Greece.
High rheumatoid factor titers can cause falsely elevated troponin I levels, a key marker for heart injury. This case highlights potential interferences in cardiac biomarker testing.
Area of Science:
- Cardiology
- Clinical Chemistry
- Immunology
Background:
- Troponin (I or T) is the primary biomarker for detecting myocardial injury.
- Immune-based assays are standard for measuring troponin I levels in clinical settings.
Observation:
- A patient presented with misleadingly elevated troponin I levels.
- The elevation was attributed to a high rheumatoid factor titer.
Findings:
- Human antibodies, specifically rheumatoid factor, can interfere with troponin I immunoassay components.
- This interference leads to inaccurate quantification of troponin I, mimicking myocardial injury.
Implications:
- Clinicians must be aware of potential interferences in troponin testing.
- Understanding molecular mechanisms of interference is crucial for accurate diagnosis and patient management.
- Consideration of rheumatoid factor levels may be necessary in specific clinical scenarios.
Related Concept Videos
Blood Studies for Cardiovascular System I: Cardiac Biomarkers
The essential diagnostic tools for detecting myocardial necrosis and monitoring individuals suspected of having acute coronary syndrome (ACS) include:
Troponins
Troponins, particularly cardiac troponins I and T, are the most precise and sensitive markers of myocardial injury. They are detectable within 4-6 hours of myocardial injury and remain...
Errors occurring during blood pressure monitoring
Several factors...
Acute Coronary Syndrome III: Diagnostic Studies
Understanding Deception
Acute Coronary Syndrome I: Introduction
Myasthenia Gravis: Diagnostic Tests