Updated: May 13, 2026

Thermal Ablation for the Treatment of Abdominal Tumors
07:16

Thermal Ablation for the Treatment of Abdominal Tumors

Published on: March 7, 2011

Endoscopic ablation systems.

Stefano Bordignon1, Kyoung-Ryul Julian Chun, Melanie Gunawardene

  • 1Cardioangiologisches Centrum Bethanien, Wilhelm-Epstein-Strasse 4, Frankfurt am Main D-60431, Germany.

Expert Review of Medical Devices
|March 14, 2013
PubMed
Summary
This summary is machine-generated.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

[2023 Annual Report of the German Pacemaker and Defibrillator Register-Part 2: Implantable cardioverter defibrillators (ICD)].

Herzschrittmachertherapie & Elektrophysiologie·2026
Same author

[Annual report 2023 of the German Pacemaker and Defibrillator Register-Part 1: Cardiac pacemaker].

Herzschrittmachertherapie & Elektrophysiologie·2026
Same author

Life-Threatening Delayed Myocardial Ischemia and Malignant Arrhythmias Occurring After Pulsed Field Ablation of Atrial Fibrillation.

Circulation·2025
Same author

One-stop strategy combining pulmonary vein isolation with balloon-in-basket pulsed field ablation and left atrial appendage closure: a case report.

European heart journal. Case reports·2025
Same author

Early Assessment of the Environmental Impact of Pentaspline Pulsed Field Ablation and Cryoablation in the Treatment of Paroxysmal Atrial Fibrillation.

Journal of health economics and outcomes research·2025
Same author

A Fly in the Ointment: Coronary Spasm After Pulsed Field Ablation of the Cavotricuspid Isthmus.

JACC. Clinical electrophysiology·2025
Same journal

Two sides to every wrist: trans-ulnar access for cardiac interventions.

Expert review of medical devices·2026
Same journal

Comparative review of coronary CT angiography versus conventional catheter angiography: diagnostic value, clinical outcomes, and underlying technical principles.

Expert review of medical devices·2026
Same journal

Assessing the MYNX CONTROL arterial vascular closure device after catheterization procedures that enter the body through the femoral arteries.

Expert review of medical devices·2026
Same journal

Efficacy of two anatomically preformed supraglottic devices, the BlockBuster Laryngeal mask airway and the Ambu AuraGain, for ventilation in anesthetised paralyzed pediatric patients: a randomized trial.

Expert review of medical devices·2026
Same journal

Prismatic treatment combined with binocular visual training for intermittent exotropia: impact on visual function and quality of life.

Expert review of medical devices·2026
Same journal

Methodological concerns in the comparative evaluation of PORTs and PICCs: limitations of indirect evidence synthesis in a recent meta-analysis.

Expert review of medical devices·2026
See all related articles

Pulmonary vein isolation using an endoscopic ablation system offers a new approach for atrial fibrillation treatment. Early studies show it is safe and effective, potentially improving cardiac arrhythmia ablation.

Area of Science:

  • Cardiology
  • Medical Technology
  • Electrophysiology

Background:

  • Pulmonary vein (PV) isolation is a standard treatment for drug-refractory atrial fibrillation.
  • Radiofrequency ablation is the current gold standard, but new technologies are emerging.
  • Anatomical variations in PV ostia can pose challenges for ablation procedures.

Purpose of the Study:

  • To evaluate the safety and efficacy of a novel endoscopic ablation system for pulmonary vein isolation.
  • To assess the potential of direct visualization in improving ablation outcomes.
  • To compare the new technology with existing pulmonary vein isolation techniques.

Main Methods:

  • Utilized an endoscopic ablation system with a compliant balloon for direct visualization of the PV ostium.

More Related Videos

Application of Laparoscopic Hepatectomy Combined with Intraoperative Microwave Ablation in Colorectal Cancer Liver Metastasis
04:22

Application of Laparoscopic Hepatectomy Combined with Intraoperative Microwave Ablation in Colorectal Cancer Liver Metastasis

Published on: March 3, 2023

Related Experiment Videos

Last Updated: May 13, 2026

Thermal Ablation for the Treatment of Abdominal Tumors
07:16

Thermal Ablation for the Treatment of Abdominal Tumors

Published on: March 7, 2011

Application of Laparoscopic Hepatectomy Combined with Intraoperative Microwave Ablation in Colorectal Cancer Liver Metastasis
04:22

Application of Laparoscopic Hepatectomy Combined with Intraoperative Microwave Ablation in Colorectal Cancer Liver Metastasis

Published on: March 3, 2023

  • Employed a laser generator for precise lesion delivery.
  • Monitored safety and efficacy in initial clinical studies.
  • Main Results:

    • The endoscopic system allows direct visualization of the PV ostium, accommodating anatomical variations.
    • The laser generator produced precise and seemingly durable lesions.
    • Initial clinical studies indicate a safety and efficacy profile comparable to established PV isolation methods.

    Conclusions:

    • The endoscopic ablation system demonstrates promising results for pulmonary vein isolation.
    • Direct visualization of the target substrate may represent a new paradigm in cardiac arrhythmia ablation.
    • Further large-scale clinical studies are needed to confirm these early findings.