Programmable on-chip and off-chip network architecture on demand for flexible optical intra-datacenters
Bijan Rahimzadeh Rofoee1, Georgios Zervas, Yan Yan
1High Performance Networks group, University of Bristol BS8 1TH, UK.
Optics Express
|March 14, 2013
Summary
This study introduces a novel network architecture on demand (AoD) approach for efficient intra-datacenter networking. The system achieves high throughput and quality of service (QoS) with hitless adaptation for optical networks.
Area of Science:
- Computer Science
- Electrical Engineering
- Telecommunications
Background:
- Intra-datacenter communication demands programmable, efficient, and transparent networking solutions.
- Existing solutions may face limitations in flexibility and adaptation for diverse traffic requirements.
Purpose of the Study:
- To present a novel network architecture on demand (AoD) approach for intra-datacenter networking.
- To enable programmable, highly efficient, and transparent networking using on-chip and off-chip implementations.
- To facilitate hitless adaptation between different optical network switching schemes.
Main Methods:
- Implementation of an FPGA-based adaptable line-card with an on-chip design.
- Development of an AoD-based off-chip flexible switching node.
- Integration of single chip dual L2-Packet/L1-time shared optical network (TSON) server Network Interface Cards (NICs).
- Interconnection through a transparent AoD-based switch.
Main Results:
- Achieved high throughput: 9.86 Gbps for Ethernet and 8.68 Gbps for TSON.
- Demonstrated high Quality of Service (QoS).
- Successfully implemented hitless adaptation between Ethernet over wavelength switched network (EoWSON) and TSON.
- Provided flexible bitrates meeting strict bandwidth requirements.
Conclusions:
- The AoD approach offers a programmable and efficient solution for intra-datacenter networking.
- The implemented system provides transparent networking with hitless adaptation capabilities.
- The solution meets stringent bandwidth and QoS requirements for modern data centers.
Related Concept Videos
Network Function of a Circuit
Frequency response analysis in electrical circuits provides vital insights into a circuit's behavior as the frequency of the input signal changes. The transfer function, a mathematical tool, is instrumental in understanding this behavior. It defines the relationship between phasor output and input and comes in four types: voltage gain, current gain, transfer impedance, and transfer admittance. The critical components of the transfer function are the poles and zeros.
Fast Decoupled and DC Powerflow
The fast decoupled power flow method addresses contingencies in power system operations, such as generator outages or transmission line failures. This method provides quick power flow solutions, essential for real-time system adjustments. Fast decoupled power flow algorithms simplify the Jacobian matrix by neglecting certain elements, leading to two sets of decoupled equations:
IP3/DAG Signaling Pathway
Membrane lipids such as phosphatidylinositol (PI) are precursors for several membrane-bound and soluble second messengers. Specific kinases phosphorylate PI and produce phosphorylated inositol phospholipids. One such inositol phospholipids are the phosphatidylinositol-4,5 bisphosphate [PI(4,5)P2], present in the inner half of the lipid bilayer. Upon ligand binding, GPCR stimulates Gq proteins to turn on phospholipase Cꞵ. Activated phospholipase Cꞵ cleaves PI(4,5)P2 and produces two-second...
Power System Distribution
Power system distribution involves delivering electrical energy from power plants to consumers through a network of transmission and distribution systems. The process begins at power plants, where energy from coal, gas, nuclear, water, and wind is converted into electrical energy. These plants use three-phase generators, typically rated between 50 to 1300 MVA, with terminal voltages ranging from a few kV to 20 kV, depending on the size and age of the units.
The transmission system is designed...
The transmission system is designed...