Related Experiment Video
Updated: May 13, 2026

Assessment of Child Anthropometry in a Large Epidemiologic Study
Published on: February 2, 2017
Evaluation of three paediatric weight estimation methods in Singapore
Pei Ying Loo1, Shu-Ling Chong, Ngee Lek
1Department of Emergency Medicine, KK Women's and Children's Hospital, Singapore. loopeiying@yahoo.com.sg
Aim:
Rapid paediatric weight estimation methods in the emergency setting have not been evaluated for South East Asian children. This study aims to assess the accuracy and precision of three such methods in Singapore children: Broselow-Luten (BL) tape, Advanced Paediatric Life Support (APLS) (estimated weight (kg) = 2 (age + 4)) and Luscombe (estimated weight (kg) = 3 (age) + 7) formulae.
Methods:
We recruited 875 patients aged 1-10 years in a Paediatric Emergency Department in Singapore over a 2-month period. For each patient, true weight and height were determined. True height was cross-referenced to the BL tape markings and used to derive estimated weight (virtual BL tape method), while patient's round-down age (in years) was used to derive estimated weights using APLS and Luscombe formulae, respectively. The percentage difference between the true and estimated weights was calculated. For each method, the bias and extent of agreement were quantified using Bland-Altman method (mean percentage difference (MPD) and 95% limits of agreement (LOA)). The proportion of weight estimates within 10% of true weight (p₁₀) was determined.
Results:
The BL tape method marginally underestimated weights (MPD +0.6%; 95% LOA -26.8% to +28.1%; p₁₀ 58.9%). The APLS formula underestimated weights (MPD +7.6%; 95% LOA -26.5% to +41.7%; p₁₀ 45.7%). The Luscombe formula overestimated weights (MPD -7.4%; 95% LOA -51.0% to +36.2%; p₁₀ 37.7%).
Conclusions:
Of the three methods we evaluated, the BL tape method provided the most accurate and precise weight estimation for Singapore children. The APLS and Luscombe formulae underestimated and overestimated the children's weights, respectively, and were considerably less precise.
Related Concept Videos
Drug Dosing in Renal Diseases: Estimation of Glomerular Filtration Rate Based on Serum Creatinine Concentration
What are Estimates?
The estimate for the mean of a sample is denoted by ͞x, whereas the mean of the population is designated as μ. Further, parameters such as the mean,...