Microwave ablation using 915-MHz and 2.45-GHz systems: what are the differences?

Kerri A Simo1, Victor B Tsirline, David Sindram

  • 1Section of Hepatobiliary and Pancreas Surgery, Carolinas Medical Center, Charlotte, NC, USA.

Summary

The 2.45-GHz microwave ablation (MWA) system offers faster and more predictable hepatic tumour ablation compared to the 915-MHz system. Both systems achieve reproducible results, but the 2.45-GHz MWA system is more efficient.

Related Concept Videos

Standing Waves in a Cavity01:28

Standing Waves in a Cavity

A household microwave and lasers are examples of standing electromagnetic waves in a cavity. When two conducting metal plates are placed parallel at the nodal planes, it creates a cavity where standing waves are formed. The cavity between the two planes is analogous to a stretched string held at the points x = 0 and x = L. Here, the distance 'L' between the two planes must be an integer multiple of half of the wavelength. The wavelengths that satisfy this condition are given by:
The Electromagnetic Spectrum01:24

The Electromagnetic Spectrum

Electromagnetic waves are categorized according to their wavelengths and frequencies, giving the electromagnetic spectrum. These waves are classified as radio, infrared, ultraviolet, etc. Radio waves refer to electromagnetic radiation with wavelengths ranging from millimeters to kilometers. Radio waves are commonly used for audio communications (i.e., radios) and typically result from an alternating current in the wires of a broadcast antenna. They cover a broad wavelength range and are used...
Atomic Emission Spectroscopy: Overview01:20

Atomic Emission Spectroscopy: Overview

Atomic emission spectroscopy (AES) is an analytical technique used to determine the elemental composition of a sample by analyzing the light emitted from excited atoms. In AES, atoms in a sample are excited to higher energy levels by thermal energy from high-temperature sources, such as plasma, arcs, or sparks. When these excited atoms return to lower energy states, they emit light at specific wavelengths characteristic of each element. The resulting atomic emission spectrum, which consists of...
Atomic Emission Spectroscopy: Interference01:30

Atomic Emission Spectroscopy: Interference

In atomic emission spectroscopy (AES), high-temperature atomizers excite a broad range of elements and molecules that generate complex emissions from sources such as oxides, hydroxides, and flame combustion products in the flame or plasma. Several strategies can be employed to minimize spectral interferences caused by overlapping emission lines or bands. These include increasing instrument resolution, choosing alternative emission lines, optimally placing the detector in low-background regions,...
Double Resonance Techniques: Overview01:12

Double Resonance Techniques: Overview

Double resonance techniques in Nuclear Magnetic Resonance (NMR) spectroscopy involve the simultaneous application of two different frequencies or radiofrequency pulses to manipulate and observe two distinct nuclear spins. One important application of double resonance is spin decoupling, which selectively suppresses coupling with one type of nucleus while observing the NMR signal from another nucleus, simplifying the spectrum and enhancing resolution.
Spin decoupling is usually achieved by...