Optimal contrast of computed tomography portal venography using dual-energy computed tomography
Qi Wang1, Gaofeng Shi, Xiang Liu
1Department of Radiology, the Fourth Clinical Hospital of Hebei Medical University, Hebei, China.
Objective:
The objective of this study was to evaluate image quality of computed tomography (CT) portal venography using nonlinear blending technique of dual-energy CT (DECT) in portal phase.
Methods:
Fifty patients underwent contrast-enhanced abdominal scan with DECT at portal venous phase. The images of 2 energy levels were mixed by a nonlinear blending filter defined by blending center (BC) and blending width (BW) and compared with linear mixing images with a ratio of 0.5. Image quality was evaluated by the images' contrast-to-noise ratios (CNRs) and the grade of visible branches of portal vein (grades 1-6). The BC and BW were optimized for the best CNRs.
Results:
The portal-to-hepatic contrast was significantly higher when the average of the liver and portal vein CT values was chosen as the BC, and 0 to 20 Hounsfield units were chosen as the BW than when using the default mixing values (80.04 [SD, 28.09] vs 38.55 [SD, 14.49] Hounsfield units, P < 0.001). In the optimized images using the nonlinear mixing technique, the mean CT values for the portal venous system and the CNRs were significantly greater than those of the linear mixing images (P < 0.001). A visible branch grade 5 or greater was assigned to 76% of the patients in the optimized group and 36% of the patients in the default linear mixing group. This difference was significant (P < 0.01).
Conclusions:
The nonlinear blending technique of DECT can improve the image quality of portal venography and show more branches of portal vein without changing the conventional scan protocol.
More Related Videos
06:02Anatomical Reconstructions of the Human Cardiac Venous System using Contrast-computed Tomography of Perfusion-fixed Specimens
Published on: April 18, 2013
09:49Dual-phase Cone-beam Computed Tomography to See, Reach, and Treat Hepatocellular Carcinoma during Drug-eluting Beads Transarterial Chemo-embolization
Published on: December 2, 2013
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System V: CT
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...