Experiment and modeling for the separation of trans-stilbene oxide enantiomers on Chiralcel OD preparative column
Rujin Gong1, Ping Li, Jianguo Yu
1State Key Laboratory of Chemical Engineering, College of Chemical Engineering, East China University of Science and Technology, Shanghai 200237, China.
Abstract:
The chromatographic enantioseparation of trans-stilbene oxide (TSO) was studied experimentally and theoretically, where the preparative column was packed with 20 μm Chiralcel OD stationary phase and hexanes/2-propanol were used as mobile phase. The bed porosity, axial dispersion coefficient, mass transfer coefficient and the column efficiency were determined according to the pulse response experiments. The adsorption equilibrium isotherms of single and racemic mixture of trans-stilbene oxide were measured by the frontal analysis, the linear-Langmuir isotherm model was used to fit the experimental data, and the relative parameters were estimated for the competitive adsorption equilibrium of TSO enantiomers. Elution profiles were measured for the separation of TSO enantiomers on Chiralcel OD preparative column, and the experimental data were compared with the simulated results predicted by the mathematical model that accounted for axial dispersion and linear driving force mass transfer model. The adsorption equilibrium and kinetic information obtained in this work are useful for the scale up and optimization of both batch and continuous chromatographic enantioseparation systems.
Related Concept Videos
Principles Of Column Chromatography
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Ion-Exchange Chromatography
Chromatography: Introduction
The phase in which the compounds linger or on which the compounds adsorb is called the stationary phase, whereas the mobile phase is the solvent that carries the solutes to be analyzed. In traditional column chromatography, the mixture flows through the stationary phase, and the compounds partition between the stationary and mobile phases...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Elution Process