Related Experiment Video
Updated: May 13, 2026

Fabrication of a Dipole-assisted Solid Phase Extraction Microchip for Trace Metal Analysis in Water Samples
Published on: August 7, 2016
Magnetic solid-phase extraction based on magnetic multi-walled carbon nanotubes for the determination of phthalate
Noushin Rastkari1, Reza Ahmadkhaniha
1Center for Air Pollution Research (CAPR), Institute for Environmental Research (IER), Tehran University of Medical Sciences, Tehran 1417614411, Iran. nr_rastkari@yahoo.com
Abstract:
In this study, magnetic carbon nanotubes (MCNTs) were prepared by assembling magnetic nanoparticles onto the acid-treated multiwall carbon nanotubes (MWCNTs). Due to their excellent adsorption capability, the MCNTs were used as adsorbent of magnetic solid-phase extraction (MSPE) to extract phthalate monoesters (PMEs), the main biomarkers of phthalate exposure, from human urine. By coupling MSPE with gas chromatography-mass spectrometry (GC-MS), a reliable, sensitive and cost-effective method for the simultaneous determination of five main PMEs including monomethyl phthalate (MMP), monoethyl phthalate (MEP), mono n-butyl phthalate (MBP), mono-(2-ethylhexyl) phthalate (MEHP) and monobenzyl phthalate (MBzP) was developed. The factors that could influence the extraction, including the amount of magnetic nanoparticles, pH of sample solution, extraction and desorption time, the amount of salt addition, the type and volume of desorption solvent were investigated in detail. Under optimized conditions, the LODs and LOQs achieved were in the range of 0.025-0.050 and 0.125-0.250 ng mL(-1) respectively. And calibration curves were linear (r(2)≥0.992) over the concentration ranges from 0.250 to 250 ng mL(-1). In addition, a satisfying reproducibility was achieved by evaluating the intra- and inter-day precisions with relative standard deviations (RSDs) less than 11.2% and 11.4%, respectively. The recoveries of the five PMEs ranged from 92.6% to 98.8% with the RSDs less than 10.7%. Finally, the established MSPE-GC-MS method was successfully applied to determine PMEs in human urine samples. MMP, MEP, MBP and MEHP were detected in most of the samples with the median concentration of 8.46, 9.26, 13.60, and 5.95 ng mL(-1) respectively. MBzP was detected in 58.3% of the samples with the median concentration of 3.05 ng mL(-1). Taken together, the MSPE-GC-MS method developed in current study provides a new option for the determination of PMEs in human urine.
More Related Videos
08:41Integration of Miniaturized Solid Phase Extraction and LC-MS/MS Detection of 3-Nitrotyrosine in Human Urine for Clinical Applications
Published on: July 14, 2017
13:35A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018