Related Experiment Video
Updated: May 13, 2026

Development of a Lateral Flow Immunochromatographic Strip for Rapid and Quantitative Detection of Small Molecule Compounds
Published on: November 13, 2021
Development of indirect competitive fluorescence immunoassay for 2,2',4,4'-tetrabromodiphenyl ether using DNA/dye
Zi-Yan Fan1, Young Soo Keum, Qing-Xiao Li
1State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-environment Sciences, Chinese Academy of Sciences, Beijing 100085, China. sumioo.van@gmail.com
Abstract:
An indirect competitive fluorescence immunoassay using a DNA/dye conjugate as antibody multiple labels was developed on 96-well plates for the identification and quantification of 2,2',4,4'-tetrabromodiphenyl ether (BDE-47) in aqueous samples. A hapten, 2,4,2'-tribromodiphenyl ether-4'-aldehyde, was synthesized, and was conjugated to bovine serum albumin to form a coating antigen. Specific recognition of the antigen by anti-PBDE antiserum was confirmed by a surface plasmon resonance measurement. In the immunoassay, the coating antigen was adsorbed on a 96-well plate first, and a sample, antiserum and biotinylated goat anti-rabbit secondary antibody were then added and reacted sequentially. A biotinylated, double-stranded DNA with 219 base pairs was attached to the secondary antibody by using streptavidin as a molecular bridge. In situ multiple labeling of the antibody was accomplished after addition of a DNA-binding fluorescent dye, SYBR Green I. The working range of the immunoassay for the BDE-47 standard was 3.1-390 microg/L, with an IC50 value of 15.6 microg/L. The calculated LOD of the immunoassay is 0.73 microg/L. The immunoassay demonstrated relatively high selectivity for BDE-47, showing very low cross-reactivity (< 3%) with BDE-15, BDE-153 and BDE-209. With a spiked river water sample containing 50 microg/L BDE-47, quantification by the immunoassay was 41.9 microg/L, which compared well with the standard GC-ECD method (45.7 microg/L). The developed immunoassay provides a rapid screening tool for polybrominated diphenyl ethers in environmental samples.
Related Concept Videos
Labeling DNA Probes
Radioisotopes, fluorophores, or small molecule binding partners like biotin or digoxigenin, are the most widely used reporter tags for labeling DNA probes. These labels can be attached to the probe DNA molecule via...
Enzyme-Linked Immunosorbent Assay
There are many different types of ELISAs, but they all involve an antibody molecule whose constant region binds an enzyme, leaving the variable region free to bind its specific antigen. Enzyme-substrate reaction allows the antigen to be visualized or quantified.
Immunofluorescence Microscopy
The...

