Related Experiment Video
Updated: May 13, 2026

Retinal Vascular Reactivity as Assessed by Optical Coherence Tomography Angiography
Published on: March 26, 2020
Carbon dioxide rebreathing in respiratory protective devices: influence of speech and work rate in full-face masks
Carmen L Smith1, Jane L Whitelaw, Brian Davies
1School of Health Sciences, University of Wollongong, Wollongong, Australia. cs847@uowmail.edu.au
Abstract:
Carbon dioxide (CO2) rebreathing has been recognised as a concern regarding respirator use and is related to symptoms of discomfort, fatigue, dizziness, headache, muscular weakness and drowsiness. Previous investigations are limited by small sample size and have not evaluated the relationship between CO2 inhalation and phonic respiration (breathing during speech) in respiratory protective devices (RPDs). A total of 40 workers trained in the use of RPDs performed a graded exercise test on a cycle ergonometer that increased in workload every 5 min. During the third minute of each stage, participants read aloud a prepared text. Measures of mixed expired CO2 (PECO2), mixed inspired CO2 (PICO2) and respiration were monitored. The results showed that phonic respiration and low work rates contributed to significantly higher levels of CO2 rebreathing. Aiming to reduce CO2 exposure may result in improved wear time of RPDs. It is recommended that these findings be incorporated in technical specifications regarding human factors for RPDs.
Practitioner Summary:
Carbon dioxide (CO2) rebreathing in respiratory protective devices (RPDs) has been highlighted as a key concern regarding respirator use. However, the problem is relatively under researched. This paper presents novel findings on the impact of phonic respiration (breathing during speech) and CO2 concentrations in RPDs.
Related Concept Videos
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Factors Affecting Respiration
Respiratory Capacities
One key metric is the Inspiratory Capacity (IC), which represents the maximum amount of air that can be inhaled with full effort. IC is calculated by summing the tidal volume and inspiratory reserve volume, typically ranging from 2.4 to 3.6 liters.
The Functional Residual Capacity (FRC) represents the air in the...
Chemical Factors Affecting Respiration Centers
CO2 has a potent influence on respiration and is strictly regulated. Under...
Other Factors Affecting Respiration Centers
However, the ability to hold one's breath voluntarily is not limitless. When the CO2 concentration in the blood reaches a critical level,...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation: