Related Experiment Video
Updated: May 13, 2026

Fentanyl Analog Screening using LC-TIMS-TOF MS/MS
Published on: November 8, 2024
Quantitative method for analysis of hydrocodone, hydromorphone and norhydrocodone in human plasma by liquid
Sandra Valtier1, Robert L Mueck, Vikhyat S Bebarta
1Clinical Research Division, 59th Medical Wing, Lackland AFB, TX 78236-5319, USA. sandra.valtier@us.af.mil
Abstract:
A selective, sensitive and accurate high-performance liquid chromatography-tandem mass spectrometry (LC-MS-MS) method for the quantitation of hydrocodone, hydromorphone and norhydrocodone in human plasma was developed. The internal standard stock solution comprised of hydrocodone-d6, hydromorphone-d6 and norhydrocodone-d3 was added to 0.5 mL plasma samples. Samples were extracted using a copolymeric sorbent (mixed mode) solid phase extraction (SPE) column. Chromatographic separation was carried out using a reversed-phase C18 analytical column with a gradient mobile phase consisting of solvent A=5% acetonitrile with 0.1% formic acid and solvent B=100% acetonitrile. MS analysis was performed using positive electrospray ionization (ESI) in multiple reaction monitoring (MRM) mode. Linearity was established over the range 1-100 ng/mL with correlation coefficients ≥0.998 for all three analytes. The coefficient of variation (CV) of intra-day samples was ≤5.6% at 10 ng/mL. The precision of inter-day (6 days) samples resulted in CVs ≤8.1% at concentrations tested at 2.5, 10 and 25 ng/mL for all three analytes. The lower limit of quantification (LOQ) was 1.0 ng/mL with signal-to-noise (S/N) ratio >10, the limit of detection (LOD) was 0.25 ng/mL with S/N ratio >3 for the drug and its metabolites. Dilution effects, extraction recovery, stability, interference, carryover and ion suppression were also evaluated. This method was successfully applied to human subject plasma samples in support of a hydrocodone pharmacokinetic study.
More Related Videos
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
09:04Identifying Per- and Polyfluorinated Chemical Species with a Combined Targeted and Non-Targeted-Screening High-Resolution Mass Spectrometry Workflow
Published on: April 18, 2019
Related Concept Videos
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
High-Performance Liquid Chromatography: Types of Detectors
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Instrumentation
High-Performance Liquid Chromatography: Elution Process