Related Experiment Video
Updated: May 12, 2026

Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
Effectiveness of cardiac resynchronization therapy with defibrillator in at-risk black and white cardiac patients
Meena Elanchenny1, Arthur J Moss, Scott McNitt
1Cardiology Unit of the Department of Medicine, University of Rochester Medical Center, Rochester, NY 14642, USA.
Insights
Black patients receiving cardiac resynchronization therapy with defibrillator (CRT-D) faced higher heart failure or death risks but showed similar echocardiographic improvements compared to white patients. Further research is needed for this population.
Area of Science:
- Cardiology
- Electrophysiology
- Medical Devices
Background:
- Limited data exists on racial disparities in cardiac resynchronization therapy with defibrillator (CRT-D) effectiveness.
- Understanding these differences is crucial for equitable heart failure management.
Purpose of the Study:
- To compare the effectiveness of CRT-D versus implantable cardioverter defibrillator (ICD) alone in white and black patients.
- To evaluate racial differences in heart failure (HF) or death risk and cardiac volume changes.
Main Methods:
- Analysis of 1638 white and 143 black patients from the MADIT-CRT trial.
- Comparison of CRT-D effectiveness against ICD therapy alone for HF/death risk and cardiac remodeling.
Main Results:
- Black patients had higher baseline comorbidities and a greater 3-year cumulative probability of HF or death (29% vs. 22%).
- Both groups showed similar, significant reductions in cardiac volumes with CRT-D.
- The risk reduction from CRT-D was not significantly different between racial groups, though the adjusted risk for HF/death in blacks was not statistically significant.
Conclusions:
- Black patients in the study had a higher risk of HF or death but responded similarly to CRT-D regarding echocardiographic changes.
- CRT-D may be effective in black patients, but further investigation in this high-risk population is warranted.
Background:
There are limited data regarding racial differences in response to cardiac resynchronization therapy with defibrillator (CRT-D).
Methods:
We assessed the effectiveness of CRT-D, as compared to implantable cardioverter defibrillator (ICD) therapy alone, in reducing the risk of heart failure (HF) or death and changes in cardiac volumes among 1638 (90%) white patients and 143 (8%) black patients enrolled in the Multicenter Automatic Defibrillator Implantation Trial with Cardiac Resynchronization Therapy (MADIT-CRT).
Results:
Enrolled black patients displayed a higher frequency of diabetes mellitus, treated hypertension, higher creatinine levels, and a lower distance walked in the baseline 6-minute walk test. Kaplan-Meier survival analysis showed that at 3 years of follow-up the cumulative probability of HF or death was higher among blacks (29%) as compared with whites (22%; P = 0.05). Both black and white patients experienced similar and pronounced reductions in cardiac volumes with CRT-D therapy (all P values for comparison between the two groups >0.10). Risk reduction conferred by CRT-D therapy as not significantly different between blacks and whites (hazard ratio = 0.78 and 0.60, respectively; P for the difference = 0.44). However, possibly due to sample size limitations the CRT-D versus ICD only adjusted risk for HF/death in blacks was not statistically significant.
Conclusions:
Black patients in MADIT-CRT experienced increased risk of HF or death as compared with whites, but displayed a similar magnitude echocardiographic response to CRT-D. These findings suggest that cardiac resynchronization therapy may be an effective therapeutic modality in black patients. However, further studies are needed to assess the clinical response to CRT-D in this high-risk population.