Related Experiment Video
Updated: Aug 18, 2026

Lesion Explorer: A Video-guided, Standardized Protocol for Accurate and Reliable MRI-derived Volumetrics in Alzheimer's Disease and Normal Elderly
Published on: April 14, 2014
MR imaging-based volume measurements of the hippocampal formation and anterior temporal lobe: validation studies
C R Jack1, M D Bentley, C K Twomey
1Department of Diagnostic Radiology, Mayo Clinic, Rochester, MN 55905.
Abstract:
An experiment was designed to compare the accuracy and reproducibility of three different techniques for in vivo magnetic resonance (MR) imaging-based volume measurements of brain structures. These techniques were tracing, thresholding, and random marking. Anterior temporal lobe (ATL) and hippocampal formation (HF) volumes in 10 volunteers were measured from MR images, as were four cylinders of known volume. The upper limit of accuracy of in vivo volume measurements is estimated to be within 0.1 cm3 of true volume for the HF and 0.9 cm3 for the ATL with a combined tracing-thresholding technique. Intra- and interobserver variations were estimated from the pooled standard deviations of HF and ATL measurements. With the combined tracing-thresholding technique, the coefficient of variation for HF measurement was 1.9%; for the ATL measurement, it was 0.7%. The results indicate that MR-based volume measurements of these brain structures can be made with high precision and reproducibility.