Combat ready clamp medic technique
The Combat Ready Clamp (CRoC) effectively controlled junctional hemorrhage in a battlefield casualty. This case report highlights the device
Area of Science:
- Trauma surgery
- Emergency medicine
- Military medicine
Background:
- Limited data exists on battlefield use of junctional hemorrhage control devices.
- The Combat Ready Clamp (CRoC) is a novel device for managing severe bleeding.
- This report details the prehospital application of the CRoC in a combat zone.
Observation:
- The CRoC was applied to manage life-threatening inguinal bleeding in a patient with a traumatic amputation.
- The device was deployed during rotary-wing casualty evacuation.
- Application time for the flight medic was 90 seconds.
Findings:
- The CRoC successfully and promptly controlled exsanguination from a critical junctional injury.
- The device performed effectively without complications during transport.
- Mechanical and physiological success was achieved with the CRoC.
Implications:
- The CRoC demonstrates utility in battlefield scenarios for controlling difficult hemorrhage.
- Successful application facilitated casualty stabilization and timely delivery to a surgical facility.
- The device enabled a less experienced medic to manage a critically injured patient effectively.
More Related Videos
07:16An Educational Video Demonstration of How to Prone a Critically Ill Intubated Patient
Published on: November 30, 2022
07:34Functional MRI in Conjunction with a Novel MRI-compatible Hand-induced Robotic Device to Evaluate Rehabilitation of Individuals Recovering from Hand Grip Deficits
Published on: November 23, 2019
Related Concept Videos
Cardiopulmonary Resuscitation II: ACLS Airway Management
Patch Clamp
In this method, a glass micropipette containing electrolyte solution is tightly sealed against a small portion of the cell membrane. As a result, a patch of the cell...
Flail Chest-II
Assessment:
1. Clinical Evaluation:
History:
Clamper Circuit
Within this circuit, the diode's orientation prompts the capacitor to charge up to the level of the most negative peak of the input signal. Upon reaching this state, the diode ceases to conduct,...
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Clipper Circuit
The operation of a clipper circuit can be exemplified by analyzing a dual-clipper configuration setup that integrates two ideal diodes, each paired with a biasing...